INTRODUCTION: Distal radioulnar joint (DRUJ) instabilities are challenging and their optimal treatment is controversial. In special cases or when reconstruction of the stabilizing triangular fibrocartilage complex (TFCC) fails, K-wire transfixation can be performed. However, no consensus has been reached regarding the rotational position of the forearm in which this should be done. Therefore, it was investigated whether anatomical reduction would best be achieved by transfixation in neutral position or supination of the forearm.
MATERIALS AND METHODS: Twelve cadaveric upper limbs were examined before dissection of the DRUJ stabilizing ligaments and after closed transfixation in both positions by C-arm cone-beam CT. Whether this was first done in neutral position or in supination was randomized. The change in the radioulnar ratio (RR) in percentage points (%points) was analyzed using Student's t-test. RR was used since it is a common and sensitive method to evaluate DRUJ reduction, expressing the ulnar head's position in the sigmoid notch as a length ratio.
RESULTS: The analysis showed an increased change in RR in neutral position with 5.4 ± 9.7%points compared to fixation in supination with 0.2 ± 16.1%points, yet this was not statistically significant (p = 0.404).
CONCLUSIONS: Neither position leads to a superior reduction in general. However, the result was slightly closer to the anatomical position in supination. Thus, transfixation of the DRUJ should be performed in the position in which reduction could best be achieved and based on these data, that tends to be in supination. Further studies are necessary to validate these findings and to identify influential factors.
MATERIALS AND METHODS: Twelve cadaveric upper limbs were examined before dissection of the DRUJ stabilizing ligaments and after closed transfixation in both positions by C-arm cone-beam CT. Whether this was first done in neutral position or in supination was randomized. The change in the radioulnar ratio (RR) in percentage points (%points) was analyzed using Student's t-test. RR was used since it is a common and sensitive method to evaluate DRUJ reduction, expressing the ulnar head's position in the sigmoid notch as a length ratio.
RESULTS: The analysis showed an increased change in RR in neutral position with 5.4 ± 9.7%points compared to fixation in supination with 0.2 ± 16.1%points, yet this was not statistically significant (p = 0.404).
CONCLUSIONS: Neither position leads to a superior reduction in general. However, the result was slightly closer to the anatomical position in supination. Thus, transfixation of the DRUJ should be performed in the position in which reduction could best be achieved and based on these data, that tends to be in supination. Further studies are necessary to validate these findings and to identify influential factors.
Full text links
Related Resources
Trending Papers
Revascularization Strategy in Myocardial Infarction with Multivessel Disease.Journal of Clinical Medicine 2024 March 27
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
Management of Diverticulitis: A Review.JAMA Surgery 2024 April 18
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app