We have located links that may give you full text access.
Cyclic High Negative-Pressure External Volume Expansion Reduces Daily Device Application Time With Similar Effects on Recipient Site Preparation in a Murine Model.
Plastic Surgery 2024 Februrary
Introduction: Recipient site preparation using external volume expansion (EVE) increases graft survival in large-volume fat grafting. To improve patient compliance with using the device, we tested a new cyclic high negative-pressure (CHNP) mode that involves 1 h/day at -55 mm Hg, cycled between 1-second negative-pressure activation, followed by a 2-second deactivation period in an animal model. Material and Method: A miniaturized EVE device was applied to 30 8-week-old male Sprague-Dawley rats. The rats were assigned to 3 groups (no pressure for the control group, conventional -25 mm Hg for 8 h/day for conventional EVE, and CHNP mode for the CHNP group). After 28 days, micro-computed tomography was performed and skin biopsy specimens were obtained. Results: The CHNP group showed a 6.6-fold increase and the conventional EVE group showed a 4.4-fold increase in volume compared to the control group. Hematoxylin and eosin staining showed a similar increase in subcutaneous tissue thickness in both EVE groups, compared to the control group. Masson's trichome and proliferating cell nuclear antigen staining showed significantly higher collagen deposition and subdermal adipocytes in EVE groups. Immunohistochemistry against platelet endothelial cell adhesion molecule 1 showed 2.5- and 2.7-times higher vessel density in the conventional and CHNP EVE groups, respectively. There was no statistically significant difference in subcutaneous tissue thickness, collagen deposition, subdermal adipocyte proliferation, and vessel density between the 2 EVE groups. Conclusion: CHNP produced comparable results in recipient site preparation (subcutaneous tissue thickening and angiogenesis) compared to the conventional protocol, while markedly reducing the daily wear-time from 8 hours to 1 hour. Although further clinical data must be acquired, our new pressure setting seems promising and provides a more patient-friendly pre-expansion environment.
Full text links
Related Resources
Trending Papers
Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of Clinical Monitoring and Computing 2024 April 31
2024 AHA/ACC/AMSSM/HRS/PACES/SCMR Guideline for the Management of Hypertrophic Cardiomyopathy: A Report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines.Circulation 2024 May 9
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app