The use of lung ultrasound in evaluation of extravascular lung water in hemodialysis patients: Systematic review and meta-analysis.

RATIONALE AND OBJECTIVES: Determining dry weight is crucial for optimizing hemodialysis, influencing efficacy, cardiovascular outcomes, and overall survival. Traditional clinical assessment methods for dry weight, relying on factors such as blood pressure and edema, frequently lack reliability. Lung ultrasound stands out as a promising tool for assessing volume status, given its non-invasiveness and reproducibility. This study aims to explore the role of Lung ultrasound in evaluating the impact of hemodialysis and ultrafiltration on extravascular lung water, with a specific focus on changes in B-lines post-hemodialysis compared to pre-hemodialysis.

MATERIALS AND METHODS: The research encompassed searches across PubMed, WOS, and Scopus databases for studies related to lung ultrasound and hemodialysis. A meta-analysis was then performed to determine the mean differences in various parameters before compared to after, hemodialysis, including the number of B-lines, indexed end-inspiratory and end-expiratory inferior vena cava diameters, inferior vena cava collapsibility index, weight, blood pressure, and serum levels of NT-pro-BNP.

RESULTS: Our meta-analysis, included 33 studies with 2301 hemodialysis patients, revealed a significant decrease in the number of B-lines post-hemodialysis (mean difference = 8.30, 95% CI [3.55 to 13.05]). Furthermore, there was a noteworthy reduction in inspiratory and expiratory inferior vena cava diameters post-hemodialysis (mean difference = 2.32, 95% CI [0.31 to 4.33]; mean difference = 4.05, 95% CI [2.44 to 5.65], respectively). Additionally, a significant positive correlation was observed between B-lines and the maximum inferior vena cava diameter both pre- and post-hemodialysis (correlation coefficient = 0.39; correlation coefficient = 0.32, respectively).

CONCLUSION: These findings indicate the effectiveness of lung ultrasound in detection of volume overload and assessment of response to ultrafiltration in hemodialysis patients.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app