We have located links that may give you full text access.
A customised down-sampling machine learning approach for sepsis prediction.
International Journal of Medical Informatics 2024 Februrary 7
OBJECTIVE: Sepsis is a life-threatening condition in the ICU and requires treatment in time. Despite the accuracy of existing sepsis prediction models, insufficient focus on reducing alarms could worsen alarm fatigue and desensitisation in ICUs, potentially compromising patient safety. In this retrospective study, we aim to develop an accurate, robust, and readily deployable method in ICUs, only based on the vital signs and laboratory tests.
METHODS: Our method consists of a customised down-sampling process and a specific dynamic sliding window and XGBoost to offer sepsis prediction. The down-sampling process was applied to the retrospective data for training the XGBoost model. During the testing stage, the dynamic sliding window and the trained XGBoost were used to predict sepsis on the retrospective datasets, PhysioNet and FHC.
RESULTS: With the filtered data from PhysioNet, our method achieved 80.74% accuracy (77.90% sensitivity and 84.42% specificity) and 83.95% (84.82% sensitivity and 82.00% specificity) on the test set of PhysioNet-A and PhysioNet-B, respectively. The AUC score was 0.89 for both datasets. On the FHC dataset, our method achieved 92.38% accuracy (88.37% sensitivity and 95.16% specificity) and 0.98 AUC score on the test set of FHC.
CONCLUSION: Our results indicate that the down-sampling process and the dynamic sliding window with XGBoost brought robust and accurate performance to give sepsis prediction under various hospital settings. The localisation and robustness of our method can assist in sepsis diagnosis in different ICU settings.
METHODS: Our method consists of a customised down-sampling process and a specific dynamic sliding window and XGBoost to offer sepsis prediction. The down-sampling process was applied to the retrospective data for training the XGBoost model. During the testing stage, the dynamic sliding window and the trained XGBoost were used to predict sepsis on the retrospective datasets, PhysioNet and FHC.
RESULTS: With the filtered data from PhysioNet, our method achieved 80.74% accuracy (77.90% sensitivity and 84.42% specificity) and 83.95% (84.82% sensitivity and 82.00% specificity) on the test set of PhysioNet-A and PhysioNet-B, respectively. The AUC score was 0.89 for both datasets. On the FHC dataset, our method achieved 92.38% accuracy (88.37% sensitivity and 95.16% specificity) and 0.98 AUC score on the test set of FHC.
CONCLUSION: Our results indicate that the down-sampling process and the dynamic sliding window with XGBoost brought robust and accurate performance to give sepsis prediction under various hospital settings. The localisation and robustness of our method can assist in sepsis diagnosis in different ICU settings.
Full text links
Related Resources
Trending Papers
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
SGLT2 Inhibitors in Kidney Diseases-A Narrative Review.International Journal of Molecular Sciences 2024 May 2
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app