The Contribution of Soft Tissue and Bony Stabilizers to the Hip Suction Seal: A Systematic Review of Biomechanical Studies.
American Journal of Sports Medicine 2024 Februrary 7
BACKGROUND: Previous biomechanical studies have identified capsular closure, labral repair or reconstruction, and osteochondroplasty as important surgical interventions to improve hip stability.
PURPOSE: To investigate the outcome metrics used to quantify hip stability and assess and measure the relative contributions of the labrum, capsule, and bone to hip stability through a quantitative analysis.
STUDY DESIGN: Systematic review and meta-analysis; Level of evidence, 4.
METHODS: PubMed and Embase databases were searched using the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Included studies evaluated cadaveric hip biomechanics related to capsular, labral, and bony management during hip arthroscopy. Studies were assessed for distraction force and distance, fluid measures, and contact forces used to quantify the suction seal. Exclusion criteria included open surgery, arthroplasty, reorientation osteotomy, or traumatic dislocation.
RESULTS: A total of 33 biomechanical studies comprising 322 hips that evaluated 1 or more of the following were included: distraction force or distance (24 studies), fluid measures (10 studies), and contact forces (6 studies). Compared with a capsulotomy or capsulectomy, capsular repair or reconstruction demonstrated greater resistance to distraction (standardized mean difference [SMD], 1.13; 95% CI, 0.46-1.80; P = .0009). Compared with a labral tear, a labral repair or reconstruction demonstrated less resistance to distraction (SMD, -0.67; 95% CI, -1.25 to -0.09; P = .02). Compared with a labral debridement, repair or reconstruction demonstrated greater resistance to distraction (SMD, 1.74; 95% CI, 1.23 to 2.26; P < .00001). No quantitative analysis was feasible from studies evaluating the effect of osseous resection due to the heterogeneity in methodology and outcome metrics assessed.
CONCLUSION: Most biomechanical evidence supports capsulotomy repair or reconstruction to improve hip distractive stability at the end of hip arthroscopic surgery. While the repair of a torn labrum does not improve distractive resistance, it is superior to labral debridement in most biomechanical studies.
PURPOSE: To investigate the outcome metrics used to quantify hip stability and assess and measure the relative contributions of the labrum, capsule, and bone to hip stability through a quantitative analysis.
STUDY DESIGN: Systematic review and meta-analysis; Level of evidence, 4.
METHODS: PubMed and Embase databases were searched using the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Included studies evaluated cadaveric hip biomechanics related to capsular, labral, and bony management during hip arthroscopy. Studies were assessed for distraction force and distance, fluid measures, and contact forces used to quantify the suction seal. Exclusion criteria included open surgery, arthroplasty, reorientation osteotomy, or traumatic dislocation.
RESULTS: A total of 33 biomechanical studies comprising 322 hips that evaluated 1 or more of the following were included: distraction force or distance (24 studies), fluid measures (10 studies), and contact forces (6 studies). Compared with a capsulotomy or capsulectomy, capsular repair or reconstruction demonstrated greater resistance to distraction (standardized mean difference [SMD], 1.13; 95% CI, 0.46-1.80; P = .0009). Compared with a labral tear, a labral repair or reconstruction demonstrated less resistance to distraction (SMD, -0.67; 95% CI, -1.25 to -0.09; P = .02). Compared with a labral debridement, repair or reconstruction demonstrated greater resistance to distraction (SMD, 1.74; 95% CI, 1.23 to 2.26; P < .00001). No quantitative analysis was feasible from studies evaluating the effect of osseous resection due to the heterogeneity in methodology and outcome metrics assessed.
CONCLUSION: Most biomechanical evidence supports capsulotomy repair or reconstruction to improve hip distractive stability at the end of hip arthroscopic surgery. While the repair of a torn labrum does not improve distractive resistance, it is superior to labral debridement in most biomechanical studies.
Full text links
Related Resources
Trending Papers
Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of Clinical Monitoring and Computing 2024 April 31
2024 AHA/ACC/AMSSM/HRS/PACES/SCMR Guideline for the Management of Hypertrophic Cardiomyopathy: A Report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines.Circulation 2024 May 9
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app