Add like
Add dislike
Add to saved papers

Rotational Thromboelastometry and Clot Waveform Analysis as Point-of-Care Tests for Diagnosis of Disseminated Intravascular Coagulation in Critically Ill Children in Thailand.

OBJECTIVES: This study aimed to determine the test performances of rotational thromboelastometry (ROTEM) and activated partial thromboplastin time-based clot waveform analysis (aPTT-CWA) compared with the International Society on Thrombosis and Hemostasis disseminated intravascular coagulation (ISTH-DIC) score for diagnosis of overt disseminated intravascular coagulation (ODIC) in critically ill children. Prognostic indicators of DIC complications were also evaluated.

DESIGN: A prospective cross-sectional observational study was conducted. ROTEM and aPTT-CWA were assessed alongside standard parameters based on the ISTH-DIC score and natural anticoagulants. Both conventional and global hemostatic tests were repeated on days 3-5 for nonovert DIC.

SETTING: PICU of the Department of Pediatrics, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.

SUBJECTS: Infants and children who were admitted to PICU with underlying diseases predisposed to DIC, such as sepsis, malignancy, major surgery, trauma, or severe illness, were included in the study between July 1, 2021, and November 30, 2022.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN RESULTS: Sixty-four children were enrolled in this study. The prevalence of ODIC was 20.3%. Regarding ROTEM parameters, using EXTEM clot formation time (CFT) cutoff of greater than 102 seconds provided sensitivity and specificity of 90.9% and 80.9%, respectively, for diagnosing ODIC, with the area under the curve (AUC) of 0.86. In the case of aPTT-CWA performance, no biphasic waveform was observed, whereas both maximum coagulation acceleration (Min2) of less than 0.35%/s2 and maximum coagulation deceleration of less than 0.25%/s2 demonstrated identical sensitivities of 76.9% and specificities of 79.6%. Combining two global hemostatic tests significantly improved the diagnostic performance (INTEM CFT + EXTEM CFT + Min2 AUC 0.92 [95% CI, 0.80-1.00] vs. EXTEM CFT AUC 0.86 [95% CI, 0.75-0.96], p = 0.034). Bleeding was the most common consequence. In multivariable logistic regression analysis, Min2 of less than 0.36%/s2 was an independent risk factor for bleeding complications, with an adjusted odds ratio of 15.08 (95% CI, 1.08-211.15, p = 0.044).

CONCLUSIONS: ROTEM and aPTT-CWA were valuable diagnostic tools in critically ill children who might require point-of-care tests. Min2 showed significant clinical implications for predicting bleeding events in this population.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app