Selective retina therapy with real-time feedback-controlled technology in central serous chorioretinopathy: a 24-month follow-up real-world prospective study.
BMJ Open Ophthalmology 2024 January 23
OBJECTIVE: Although central serous chorioretinopathy (CSC) treatment using selective retinal therapy (SRT) has presented favourable outcomes, no long-term studies with a real-world clinical practice regimen have been conducted.
METHODS AND ANALYSIS: We performed a long-term assessment of CSC treatment using SRT with real-time feedback (RTF) technology. 50 patients (53 eyes) with CSC and more than a 1-month symptom duration were recruited and treated with SRT using a 1.7 µs pulse width, 527 nm neodymium-doped yttrium lithium fluoride (Nd:YLF) laser equipped with an RTF system.
RESULTS: After 6 months of treatment, complete subretinal fluid resolution was achieved in 62% of the eyes. The mean best-corrected visual acuity (BCVA; logarithm of the minimum angle of resolution, mean±SD) improved slightly from 0.15±0.18 at baseline to 0.12±0.21 at 6 months (p=0.062). The central retinal thickness (CRT; mean±SD) was reduced significantly from 350.6±100.1 µm at baseline to 268.2±70.6 µm at 6 months (p<0.001). Long-term follow-up revealed significant improvements in BCVA, from 9 months until 24 months, and in CRT, from 1 month until 24 months. No treatment-related adverse events were observed during the 24-month follow-up period.
CONCLUSION: Our results suggest that SRT with RTF technology is a long-term safe treatment with anatomical improvement for patients with CSC.
METHODS AND ANALYSIS: We performed a long-term assessment of CSC treatment using SRT with real-time feedback (RTF) technology. 50 patients (53 eyes) with CSC and more than a 1-month symptom duration were recruited and treated with SRT using a 1.7 µs pulse width, 527 nm neodymium-doped yttrium lithium fluoride (Nd:YLF) laser equipped with an RTF system.
RESULTS: After 6 months of treatment, complete subretinal fluid resolution was achieved in 62% of the eyes. The mean best-corrected visual acuity (BCVA; logarithm of the minimum angle of resolution, mean±SD) improved slightly from 0.15±0.18 at baseline to 0.12±0.21 at 6 months (p=0.062). The central retinal thickness (CRT; mean±SD) was reduced significantly from 350.6±100.1 µm at baseline to 268.2±70.6 µm at 6 months (p<0.001). Long-term follow-up revealed significant improvements in BCVA, from 9 months until 24 months, and in CRT, from 1 month until 24 months. No treatment-related adverse events were observed during the 24-month follow-up period.
CONCLUSION: Our results suggest that SRT with RTF technology is a long-term safe treatment with anatomical improvement for patients with CSC.
Full text links
Related Resources
Trending Papers
Renin-Angiotensin-Aldosterone System: From History to Practice of a Secular Topic.International Journal of Molecular Sciences 2024 April 5
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
British Society for Rheumatology guideline on management of adult and juvenile onset Sjögren disease.Rheumatology 2024 April 17
Albumin: a comprehensive review and practical guideline for clinical use.European Journal of Clinical Pharmacology 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app