We have located links that may give you full text access.
Use of the Aurolab Aqueous Drainage Implant as a buckling element in pediatric retinal detachment with a preexisting glaucoma drainage device.
PURPOSE: To describe a novel technique for repair of rhegmatogenous retinal detachment in an eye with a previous non-valved glaucoma drainage device, the Aurolab Aqueous Drainage Implant (AADI).
OBSERVATIONS: A 5-year-old child with bilateral primary congenital glaucoma presented with an inferior retinal detachment (RD) in the left eye. The left eye had a history of multiple surgical interventions including combined trabeculotomy and trabeculectomy done twice, AADI implantation and subsequently phacoaspiration with IOL implantation, 18 months prior to presentation. The left eye retinal detachment was managed by scleral buckling technique using the plate of the AADI as a buckling element without its explantation.
CONCLUSIONS: AND IMPORTANCE: Management of retinal detachment in eyes with a pre-existing glaucoma drainage device (GDD) is uniquely challenging. Explantation of the GDD would likely result in intractable glaucoma post-operatively, requiring another surgery. Use of the trimmed plate of the GDD itself as the buckling element helped in settling the RD and preserving intraocular pressure control.
OBSERVATIONS: A 5-year-old child with bilateral primary congenital glaucoma presented with an inferior retinal detachment (RD) in the left eye. The left eye had a history of multiple surgical interventions including combined trabeculotomy and trabeculectomy done twice, AADI implantation and subsequently phacoaspiration with IOL implantation, 18 months prior to presentation. The left eye retinal detachment was managed by scleral buckling technique using the plate of the AADI as a buckling element without its explantation.
CONCLUSIONS: AND IMPORTANCE: Management of retinal detachment in eyes with a pre-existing glaucoma drainage device (GDD) is uniquely challenging. Explantation of the GDD would likely result in intractable glaucoma post-operatively, requiring another surgery. Use of the trimmed plate of the GDD itself as the buckling element helped in settling the RD and preserving intraocular pressure control.
Full text links
Related Resources
Trending Papers
Revascularization Strategy in Myocardial Infarction with Multivessel Disease.Journal of Clinical Medicine 2024 March 27
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
Management of Diverticulitis: A Review.JAMA Surgery 2024 April 18
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app