Add like
Add dislike
Add to saved papers

Ruggedized Self-Propelling Hemostatic Gauze Delivers Low Dose of Thrombin and Systemic Tranexamic Acid and Achieves High Survival in Swine With Junctional Hemorrhage.

Military Medicine 2023 November 9
INTRODUCTION: Hemorrhage is responsible for 91% of preventable prehospital deaths in combat. Bleeding from anatomic junctions such as the groin, neck, and axillae make up 19% of these deaths, and reports estimate that effective control of junctional hemorrhage could have prevented 5% of fatalities in Afghanistan. Hemostatic dressings are effective but are time-consuming to apply and are limited when proper packing and manual pressure are not feasible, such as during care under fire. CounterFlow-Gauze is a hemostatic dressing that is effective without compression and delivers thrombin and tranexamic acid into wounds. Here, an advanced prototype of CounterFlow-Gauze, containing a range of low thrombin doses, was tested in a lethal swine model of junctional hemorrhage. Outcomes were compared with those of Combat Gauze, the current dressing recommended by Tactical Combat Casualty Care.

MATERIALS AND METHODS: CounterFlow-Gauze containing thrombin doses of 0, 20, 200, and 500 IU was prepared. Swine received femoral arteriotomies, and CounterFlow-Gauze was packed into wounds without additional manual compression. In a separate study using a similar model of junctional hemorrhage without additional compression, CounterFlow-Gauze containing 500 IU thrombin was tested and compared with Combat Gauze. In both studies, the primary outcomes were survival to 3 h and volume of blood loss.

RESULTS: CounterFlow-Gauze with 200 and 500 IU had the highest 3-h survival, achieving 70 and 75% survival, respectively. CounterFlow-Gauze resulted in mean peak plasma tranexamic acid concentrations of 9.6 ± 1.0 µg/mL (mean ± SEM) within 3 h. In a separate study with smaller injury, CounterFlow-Gauze with 500 IU achieved 100% survival to 3 h compared with 92% in Combat Gauze animals.

CONCLUSIONS: An advanced preclinical prototype of CounterFlow-Gauze formulated with a minimized thrombin dose is highly effective at managing junctional hemorrhage without compression. These results demonstrate that CounterFlow-Gauze could be developed into a feasible alternative to Combat Gauze for hemorrhage control on the battlefield.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app