Fixation of a modular curved revision stem with a taper of 2° in the femur.
Archives of Orthopaedic and Trauma Surgery 2018 November 11
INTRODUCTION: Modular revision stems with a short distal component can prevent the bypassing of the femoral isthmus and hereby theoretically have advantages concerning risk of periprosthetic fractures, breakage of the junction and a technically easier revision procedure.
MATERIALS AND METHODS: Radiological evaluation of 202 stem revision operations with the modular curved revision stem "Revitan Curved" with a 2° taper was carried out after a mean follow-up period of 7.44 ± 2.09 years (3-13 years) to investigate whether short-stem combinations are effective in Paprosky 2 and 3A defects with respect to rate of subsidence and loosening.
RESULTS: Sixty of 62 endofemoral (96.8%) and 137 of 140 transfemoral implantations (97.9%) involved the short, 140 mm distal component. Significant subsidence was seen in 3.3% of cases following endofemoral implantation and in 2.1% of cases following transfemoral implantation. Neither aseptic loosening nor periprosthetic fracture were observed.
CONCLUSION: The use of combinations of short modular components leads to reproducibly good outcomes in femoral revision with respect to subsidence and loosening.
MATERIALS AND METHODS: Radiological evaluation of 202 stem revision operations with the modular curved revision stem "Revitan Curved" with a 2° taper was carried out after a mean follow-up period of 7.44 ± 2.09 years (3-13 years) to investigate whether short-stem combinations are effective in Paprosky 2 and 3A defects with respect to rate of subsidence and loosening.
RESULTS: Sixty of 62 endofemoral (96.8%) and 137 of 140 transfemoral implantations (97.9%) involved the short, 140 mm distal component. Significant subsidence was seen in 3.3% of cases following endofemoral implantation and in 2.1% of cases following transfemoral implantation. Neither aseptic loosening nor periprosthetic fracture were observed.
CONCLUSION: The use of combinations of short modular components leads to reproducibly good outcomes in femoral revision with respect to subsidence and loosening.
Full text links
Related Resources
Trending Papers
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Finerenone: From the Mechanism of Action to Clinical Use in Kidney Disease.Pharmaceuticals 2024 March 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app