We have located links that may give you full text access.
A machine learning pipeline for internal anatomical landmark embedding based on a patient surface model.
International Journal of Computer Assisted Radiology and Surgery 2018 October 14
PURPOSE: With the recent introduction of fully assisting scanner technologies by Siemens Healthineers (Erlangen, Germany), a patient surface model was introduced to the diagnostic imaging device market. Such a patient representation can be used to automate and accelerate the clinical imaging workflow, manage patient dose, and provide navigation assistance for computed tomography diagnostic imaging. In addition to diagnostic imaging, a patient surface model has also tremendous potential to simplify interventional imaging. For example, if the anatomy of a patient was known, a robotic angiography system could be automatically positioned such that the organ of interest is positioned in the system's iso-center offering a good and flexible view on the underlying patient anatomy quickly and without any additional X-ray dose.
METHOD: To enable such functionality in a clinical context with sufficiently high accuracy, we present an extension of our previous patient surface model by adding internal anatomical landmarks associated with certain (main) bones of the human skeleton, in particular the spine. We also investigate different approaches to positioning of these landmarks employing CT datasets with annotated internal landmarks as training data. The general pipeline of our proposed method comprises the following steps: First, we train an active shape model using an existing avatar database and segmented CT surfaces. This stage also includes a gravity correction procedure, which accounts for shape changes due to the fact that the avatar models were obtained in standing position, while the CT data were acquired with patients in supine position. Second, we match the gravity-corrected avatar patient surface models to surfaces segmented from the CT datasets. In the last step, we derive the spatial relationships between the patient surface model and internal anatomical landmarks.
RESULT: We trained and evaluated our method using cross-validation using 20 datasets, each containing 50 internal landmarks. We further compared the performance of four different generalized linear models' setups to describe the positioning of the internal landmarks relative to the patient surface. The best mean estimation error over all the landmarks was achieved using lasso regression with a mean error of [Formula: see text].
CONCLUSION: Considering that interventional X-ray imaging systems can have detectors covering an area of about [Formula: see text] ([Formula: see text]) at iso-center, this accuracy is sufficient to facilitate automatic positioning of the X-ray system.
METHOD: To enable such functionality in a clinical context with sufficiently high accuracy, we present an extension of our previous patient surface model by adding internal anatomical landmarks associated with certain (main) bones of the human skeleton, in particular the spine. We also investigate different approaches to positioning of these landmarks employing CT datasets with annotated internal landmarks as training data. The general pipeline of our proposed method comprises the following steps: First, we train an active shape model using an existing avatar database and segmented CT surfaces. This stage also includes a gravity correction procedure, which accounts for shape changes due to the fact that the avatar models were obtained in standing position, while the CT data were acquired with patients in supine position. Second, we match the gravity-corrected avatar patient surface models to surfaces segmented from the CT datasets. In the last step, we derive the spatial relationships between the patient surface model and internal anatomical landmarks.
RESULT: We trained and evaluated our method using cross-validation using 20 datasets, each containing 50 internal landmarks. We further compared the performance of four different generalized linear models' setups to describe the positioning of the internal landmarks relative to the patient surface. The best mean estimation error over all the landmarks was achieved using lasso regression with a mean error of [Formula: see text].
CONCLUSION: Considering that interventional X-ray imaging systems can have detectors covering an area of about [Formula: see text] ([Formula: see text]) at iso-center, this accuracy is sufficient to facilitate automatic positioning of the X-ray system.
Full text links
Related Resources
Trending Papers
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Finerenone: From the Mechanism of Action to Clinical Use in Kidney Disease.Pharmaceuticals 2024 March 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app