Locking plate osteosynthesis for a femoral fracture and subsequent nonunion in a patient with osteopetrosis.
INTRODUCTION: Osteopetrosis is a skeletal disorder characterized by increased osteodensity and a remodeling defect. The fragility of dense sclerotic bones may lead to an increased incidence of fractures. Although internal fixation can be performed, technical challenges may be experienced because of the increased bone density. Complications such as delayed union, nonunion, or implant failure may occur postoperatively.
PRESENTATION OF CASE: We describe a patient with autosomal-dominant osteopetrosis type 2 who suffered a shaft fracture below a plate of his right femur. We performed osteosynthesis with a single locking plate. Union was delayed, and plate breakage occurred along with nonunion of the fracture. The nonunion was addressed using double locking plates, which secured fixation and allowed complete fracture healing.
DISCUSSION: There were three reasons of nonunion in our case. First, we left gaps between the fragments. Second, we used mainly cerclage wires, rather than screws, for plate fixation, which led to inadequate stability. Third, the patient was large (height 167 cm, weight 93.1 kg), so the single plate provided insufficient fixing force. We then used double locking plates and attained stronger internal fixation with complete fracture healing.
CONCLUSION: Double plating with locking plates may be an effective treatment option for femoral fractures in patients with osteopetrosis.
PRESENTATION OF CASE: We describe a patient with autosomal-dominant osteopetrosis type 2 who suffered a shaft fracture below a plate of his right femur. We performed osteosynthesis with a single locking plate. Union was delayed, and plate breakage occurred along with nonunion of the fracture. The nonunion was addressed using double locking plates, which secured fixation and allowed complete fracture healing.
DISCUSSION: There were three reasons of nonunion in our case. First, we left gaps between the fragments. Second, we used mainly cerclage wires, rather than screws, for plate fixation, which led to inadequate stability. Third, the patient was large (height 167 cm, weight 93.1 kg), so the single plate provided insufficient fixing force. We then used double locking plates and attained stronger internal fixation with complete fracture healing.
CONCLUSION: Double plating with locking plates may be an effective treatment option for femoral fractures in patients with osteopetrosis.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app