We have located links that may give you full text access.
Fretting and Corrosion Damage in Retrieved Metal-on-Polyethylene Modular Total Hip Arthroplasty Systems: What Is the Importance of Femoral Head Size?
Journal of Arthroplasty 2018 March
BACKGROUND: Fretting and corrosion at the modular femoral head-femoral neck (taper) interface have been reported in retrieved total hip arthroplasty (THA) prostheses. This study investigated associations among implant design, radiographic factors, and patient factors with corrosion and fretting at the taper interface in retrieved metal-on-polyethylene modular THA prostheses.
METHODS: Ninety-two retrieved primary metal-on-polyethylene THA implants were evaluated and graded for fretting, corrosion, and damage at the taper interface, including the femoral stem trunnion and femoral head. Preoperative radiographs were assessed for osteolysis and femoral stem alignment; and medical records were reviewed for demographic data.
RESULTS: Male patients had greater head corrosion (P = .037), patient age at revision had a weak, negative correlation with trunnion corrosion (ρ = -0.20, P = .04), and both body mass index and duration of implantation had weak, positive correlations with head fretting (ρ = 0.26, P = .01 and ρ = 0.33, P = .001, respectively). A weak, negative correlation was found between femoral head size and both head fretting and head corrosion (ρ = -0.26, P = .007 and ρ = -0.21, P = .028, respectively), and a weak, positive correlation was found between head offset and trunnion fretting (ρ = 0.23, P = .030). Varus femoral stem alignment was associated with greater head fretting (P = .038).
CONCLUSION: Larger femoral head sizes were correlated with less severe head corrosion and head fretting, with 28-mm heads exhibiting more moderate-to-severe damage. Other factors, such as head-taper engagement and geometry, rather than head size, may affect rates of corrosion and fretting damage at the taper interface.
METHODS: Ninety-two retrieved primary metal-on-polyethylene THA implants were evaluated and graded for fretting, corrosion, and damage at the taper interface, including the femoral stem trunnion and femoral head. Preoperative radiographs were assessed for osteolysis and femoral stem alignment; and medical records were reviewed for demographic data.
RESULTS: Male patients had greater head corrosion (P = .037), patient age at revision had a weak, negative correlation with trunnion corrosion (ρ = -0.20, P = .04), and both body mass index and duration of implantation had weak, positive correlations with head fretting (ρ = 0.26, P = .01 and ρ = 0.33, P = .001, respectively). A weak, negative correlation was found between femoral head size and both head fretting and head corrosion (ρ = -0.26, P = .007 and ρ = -0.21, P = .028, respectively), and a weak, positive correlation was found between head offset and trunnion fretting (ρ = 0.23, P = .030). Varus femoral stem alignment was associated with greater head fretting (P = .038).
CONCLUSION: Larger femoral head sizes were correlated with less severe head corrosion and head fretting, with 28-mm heads exhibiting more moderate-to-severe damage. Other factors, such as head-taper engagement and geometry, rather than head size, may affect rates of corrosion and fretting damage at the taper interface.
Full text links
Related Resources
Trending Papers
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Review article: Recent advances in ascites and acute kidney injury management in cirrhosis.Alimentary Pharmacology & Therapeutics 2024 March 26
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app