We have located links that may give you full text access.
Reliable screening and confirmation of 156 multi-class illegal adulterants in dietary supplements based on extracted common ion chromatograms by ultra-high-performance liquid chromatography-quadrupole/time of flight-mass spectrometry.
Journal of Chromatography. A 2017 March 32
An analytical method for the reliable screening and confirmation of 156 illegal drugs (58 erectile dysfunction drugs, 49 synthetic steroids, 26 anabolic steroids, and 23 anti-histamine drugs) in supplementary diets using ultra-high-performance liquid chromatography coupled with quadrupole/time-of-flight mass spectrometry (UHPLC-Q/TOF-MS) was developed. Various types of supplements (liquid, capsule, powder, pill and tablet) with complicated matrices were pretreated by simple liquid-liquid extraction. The wide scope of 156 target compounds was effectively determined within 15min in the positive ion mode, detecting the compounds at a sub-ppb level. Their MS/MS spectra were preferentially investigated to find diagnostic common ions according to the structural similarity of diverse adulterants. For the rapid screening of multiple classes of the target adulterants, extracted common ion chromatograms (ECICs) based on specific fragments of similar molecular moieties were attempted. A database including the elemental compositions, retention times, and MS/MS spectra was built for the confirmation of adulterants. The established method was validated in terms of the linearity, limits of detection (LOD), precision, and accuracy. The linear correlation coefficient and limit of detection ranged from 0.9880 to 1 and from 0.02 to 16.04ng/mL, respectively. The precision and accuracy of intra- and inter-day experiments for the spiked samples at the range of 0.2 and 16.0ng/mL were from 0.16 to 13.50% and 0.19-11.48%, respectively, with relative standard deviation. Mean recoveries ranged from 81.6 to 124.7%, and relative standard deviation was less than 9.20%. The screening and confirmation method demonstrated the usefulness of UHPLC-Q/TOF-MS combined with ECICs as a promising approach for the analysis of multi-class adulterants. Finally, the established method was successfully applied for the monitoring of several types of dietary supplements in routine analysis.
Full text links
Related Resources
Trending Papers
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Finerenone: From the Mechanism of Action to Clinical Use in Kidney Disease.Pharmaceuticals 2024 March 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app