We have located links that may give you full text access.
Journal Article
Observational Study
Influence of different infracardial positions of central venous catheters in hemodynamic monitoring using the transpulmonal thermodilution method.
Journal of Clinical Monitoring and Computing 2016 October
Hemodynamic measurements are often conducted by the transpulmonary thermodilution (TPTD)-based PiCCO(®)-system. This requires a central-venous (CVC) and a thermistor-tipped arterial catheter, usually placed in the femoral artery. In certain clinical situations, CVC devices have to be placed in the inferior vena cava. However, little is known about the influence of different CVC positions (i.e. ipsi- vs. contra-lateral to the arterial catheter) on the accuracy of the TPTD measurement results. In this prospective observational study surgical intensive care unit patients who had been inserted with CVCs either into the superior (CVCVCS) or the inferior vena cava (CVCinf) in addition to an arterial PiCCO(®)-catheter, were enrolled. Patients were then divided into two groups: Group I was provided with a CVC in the contralateral (CVCcontra) and Group II in the ipsilateral (CVCipsi) inferior vena cava. Thermodilution via injection of ice-cold saline was then performed via CVCsup and CVCinf. Bland-Altman analysis for cardiac index (CI), extra-vascular lung water index (EVLWI) and global end-diastolic volume index (GEDVI) were employed. Additional correction formulas for femorally assed parameters were determined. In a total of 28 patients, bias (limits of agreement) for measurements of CI in CVCcontra was found to be +0.2 (-0.4; +0.9) and +0.3 (-0.4; +1.0) L/min/m(2) in CVCipsi. GEDVI showed a bias of +274.8 (-47.3; +596.9) mL/m(2) in CVCcontra and +274.7 (-100.7; +650.1) mL/m(2) in CVCipsi. The mean EVLWI were 9.4 ± 4.3 mL/kg for EVLWIVCS and 10.7 ± 5.2 mL/kg for EVLWIinf. The LoA yielded at -3.4 and +6.1 mL/kg with a bias of +1.3 mL/kg. Percentage errors revealed clinically acceptable limits for CI and GEDVI, but not for EVLWI. Using TPTD via an infracardial central vein, measurements of CI showed high accuracy and precision while GEDVI measurements were precise with a lower accuracy, irrespective of the position of the infracardial CVC.
Full text links
Related Resources
Trending Papers
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Review article: Recent advances in ascites and acute kidney injury management in cirrhosis.Alimentary Pharmacology & Therapeutics 2024 March 26
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app