Electrical-mechanical dynamical coupling between electrocardiographic and photoplethysmographic signals during cardiopulmonary resuscitation.
Computer Methods and Programs in Biomedicine 2023 September 24
BACKGROUND AND OBJECTIVE: Cardiac arrest (CA) remains a significant cause of death and disability. High-quality cardiopulmonary resuscitation (CPR) can improve the survival rate of CA. A challenging issue is to find physiological indicators for screening and evaluating the cardiovascular function associated with CPR. This study aimed to investigate the electrical-mechanical dynamic coupling between electrocardiographic (ECG) and photoplethysmographic (PPG) signals for indicating cardiovascular function in the progress of CPR.
METHOD: The ECG and PPG signals were simultaneously collected from a porcine CA model (n = 10) induced by ventricular fibrillation, and were further divided into four periods: Baseline, CA, CPR, and recovery of spontaneous circulation (ROSC). Recurrence quantitative analysis (RQA) was applied to examine the nonlinear dynamics of the ECG and PPG signals individually, and cross recurrence quantitative analysis (CRQA) was used to examine the ECG-PPG dynamical coupling.
RESULTS: The CA influenced the dynamic patterns of electrical and mechanical activities and the electrical-mechanical coupling, which can be observed from the reduced entropy (ENTR) (p < 0.01), reduced determinism (DET) (p < 0.01) and reduced trapping time (TT) (p < 0.01) at CA compared to Baseline. The recurrence rate (RR), ENTR, DET, and TT at CPR were significantly lower than the parameters at ROSC but higher than those at CA.
CONCLUSIONS: The electrical-mechanical dynamical coupling was sensitive to CPR and able to reflect the changes in cardiac function in the process of CPR.
METHOD: The ECG and PPG signals were simultaneously collected from a porcine CA model (n = 10) induced by ventricular fibrillation, and were further divided into four periods: Baseline, CA, CPR, and recovery of spontaneous circulation (ROSC). Recurrence quantitative analysis (RQA) was applied to examine the nonlinear dynamics of the ECG and PPG signals individually, and cross recurrence quantitative analysis (CRQA) was used to examine the ECG-PPG dynamical coupling.
RESULTS: The CA influenced the dynamic patterns of electrical and mechanical activities and the electrical-mechanical coupling, which can be observed from the reduced entropy (ENTR) (p < 0.01), reduced determinism (DET) (p < 0.01) and reduced trapping time (TT) (p < 0.01) at CA compared to Baseline. The recurrence rate (RR), ENTR, DET, and TT at CPR were significantly lower than the parameters at ROSC but higher than those at CA.
CONCLUSIONS: The electrical-mechanical dynamical coupling was sensitive to CPR and able to reflect the changes in cardiac function in the process of CPR.
Full text links
Related Resources
Trending Papers
Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of Clinical Monitoring and Computing 2024 April 31
2024 AHA/ACC/AMSSM/HRS/PACES/SCMR Guideline for the Management of Hypertrophic Cardiomyopathy: A Report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines.Circulation 2024 May 9
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app