We have located links that may give you full text access.
Deep Learning Super-Resolution Reconstruction for Fast and Motion-Robust T2-weighted Prostate MRI.
Radiology 2023 September
Background Deep learning (DL) reconstructions can enhance image quality while decreasing MRI acquisition time. However, DL reconstruction methods combined with compressed sensing for prostate MRI have not been well studied. Purpose To use an industry-developed DL algorithm to reconstruct low-resolution T2-weighted turbo spin-echo (TSE) prostate MRI scans and compare these with standard sequences. Materials and Methods In this prospective study, participants with suspected prostate cancer underwent prostate MRI with a Cartesian standard-resolution T2-weighted TSE sequence (T2C ) and non-Cartesian standard-resolution T2-weighted TSE sequence (T2NC ) between August and November 2022. Additionally, a low-resolution Cartesian DL-reconstructed T2-weighted TSE sequence (T2DL ) with compressed sensing DL denoising and resolution upscaling reconstruction was acquired. Image sharpness was assessed qualitatively by two readers using a five-point Likert scale (from 1 = nondiagnostic to 5 = excellent) and quantitatively by calculating edge rise distance. The Friedman test and one-way analysis of variance with post hoc Bonferroni and Tukey tests, respectively, were used for group comparisons. Prostate Imaging Reporting and Data System (PI-RADS) score agreement between sequences was compared by using Cohen κ. Results This study included 109 male participants (mean age, 68 years ± 8 [SD]). Acquisition time of T2DL was 36% and 29% lower compared with that of T2C and T2NC (mean duration, 164 seconds ± 20 vs 257 seconds ± 32 and 230 seconds ± 28; P < .001 for both). T2DL showed improved image sharpness compared with standard sequences using both qualitative (median score, 5 [IQR, 4-5] vs 4 [IQR, 3-4] for T2C and 4 [IQR, 3-4] for T2NC ; P < .001 for both) and quantitative (mean edge rise distance, 0.75 mm ± 0.39 vs 1.15 mm ± 0.68 for T2C and 0.98 mm ± 0.65 for T2NC ; P < .001 and P = .01) methods. PI-RADS score agreement between T2NC and T2DL was excellent (κ range, 0.92-0.94 [95% CI: 0.87, 0.98]). Conclusion DL reconstruction of low-resolution T2-weighted TSE sequences enabled accelerated acquisition times and improved image quality compared with standard acquisitions while showing excellent agreement with conventional sequences for PI-RADS ratings. Clinical trial registration no. NCT05820113 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Turkbey in this issue.
Full text links
Related Resources
Trending Papers
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of Clinical Monitoring and Computing 2024 April 31
SGLT2 Inhibitors in Kidney Diseases-A Narrative Review.International Journal of Molecular Sciences 2024 May 2
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app