Add like
Add dislike
Add to saved papers

Contrast-Enhanced Liver Magnetic Resonance Image Synthesis Using Gradient Regularized Multi-Modal Multi-Discrimination Sparse Attention Fusion GAN.

Cancers 2023 July 9
PURPOSES: To provide abdominal contrast-enhanced MR image synthesis, we developed an gradient regularized multi-modal multi-discrimination sparse attention fusion generative adversarial network (GRMM-GAN) to avoid repeated contrast injections to patients and facilitate adaptive monitoring.

METHODS: With IRB approval, 165 abdominal MR studies from 61 liver cancer patients were retrospectively solicited from our institutional database. Each study included T2, T1 pre-contrast (T1pre), and T1 contrast-enhanced (T1ce) images. The GRMM-GAN synthesis pipeline consists of a sparse attention fusion network, an image gradient regularizer (GR), and a generative adversarial network with multi-discrimination. The studies were randomly divided into 115 for training, 20 for validation, and 30 for testing. The two pre-contrast MR modalities, T2 and T1pre images, were adopted as inputs in the training phase. The T1ce image at the portal venous phase was used as an output. The synthesized T1ce images were compared with the ground truth T1ce images. The evaluation metrics include peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), and mean squared error (MSE). A Turing test and experts' contours evaluated the image synthesis quality.

RESULTS: The proposed GRMM-GAN model achieved a PSNR of 28.56, an SSIM of 0.869, and an MSE of 83.27. The proposed model showed statistically significant improvements in all metrics tested with p -values < 0.05 over the state-of-the-art model comparisons. The average Turing test score was 52.33%, which is close to random guessing, supporting the model's effectiveness for clinical application. In the tumor-specific region analysis, the average tumor contrast-to-noise ratio (CNR) of the synthesized MR images was not statistically significant from the real MR images. The average DICE from real vs. synthetic images was 0.90 compared to the inter-operator DICE of 0.91.

CONCLUSION: We demonstrated the function of a novel multi-modal MR image synthesis neural network GRMM-GAN for T1ce MR synthesis based on pre-contrast T1 and T2 MR images. GRMM-GAN shows promise for avoiding repeated contrast injections during radiation therapy treatment.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app