Challenging the Perceptions of Human Tendon Allografts: Influence of Donor Age, Sex, Height, and Tendon on Biomechanical Properties.
American Journal of Sports Medicine 2023 January 4
BACKGROUND: The use of allograft tendons has increased for primary and revision anterior cruciate ligament reconstruction, but allograft supply is currently limited to a narrow range of tendons and donors up to the age of 65 years. Expanding the range of donors and tendons could help offset an increasing clinical demand.
PURPOSE: To investigate the effects of donor age, sex, height, and specific tendon on the mechanical properties of a range of human lower leg tendons.
STUDY DESIGN: Descriptive laboratory study.
METHODS: Nine tendons were retrieved from 39 fresh-frozen human cadaveric lower legs (35 donors [13 female, 22 male]; age, 49-99 years; height, 57-85 inches [145-216 cm]) including: Achilles tendon, tibialis posterior and anterior, fibularis longus and brevis, flexor and extensor hallucis longus, plantaris, and flexor digitorum longus. Tendons underwent tensile loading to failure measuring cross-sectional area (CSA), maximum load, strain at failure, ultimate tensile strength, and elastic modulus. Results from 332 tendons were analyzed using mixed-effects linear regression, accounting for donor age, sex, height, and weight.
RESULTS: Mechanical properties were significantly different among tendons and were substantially greater than the effects of donor characteristics. Significant effects of donor sex, age, and height were limited to specific tendons: Achilles tendon, tibialis posterior, and tibialis anterior. All other tendons were unaffected. The Achilles tendon was most influenced by donor variables: greater CSA in men (β = 15.45 mm2 ; Šidák adjusted P < .0001), decreased maximum load with each year of increased age (β = -17.20 N per year; adjusted P = .0253), and increased CSA (β = 1.92 mm2 per inch; adjusted P < .0001) and maximum load (β = 86.40 N per inch; adjusted P < .0001) with each inch of increased height.
CONCLUSION: Mechanical properties vary significantly across different human tendons. The effects of donor age, sex, and height are relatively small, are limited to specific tendons, and affect different tendons uniquely. The findings indicate that age negatively affected only the Achilles tendon (maximum load) and challenge the exclusion of donors aged >65 years across all tendon grafts.
CLINICAL RELEVANCE: The findings support including a broader range of tendons for use as allografts for anterior cruciate ligament reconstruction and reviewing the current exclusion criterion of donors aged >65 years.
PURPOSE: To investigate the effects of donor age, sex, height, and specific tendon on the mechanical properties of a range of human lower leg tendons.
STUDY DESIGN: Descriptive laboratory study.
METHODS: Nine tendons were retrieved from 39 fresh-frozen human cadaveric lower legs (35 donors [13 female, 22 male]; age, 49-99 years; height, 57-85 inches [145-216 cm]) including: Achilles tendon, tibialis posterior and anterior, fibularis longus and brevis, flexor and extensor hallucis longus, plantaris, and flexor digitorum longus. Tendons underwent tensile loading to failure measuring cross-sectional area (CSA), maximum load, strain at failure, ultimate tensile strength, and elastic modulus. Results from 332 tendons were analyzed using mixed-effects linear regression, accounting for donor age, sex, height, and weight.
RESULTS: Mechanical properties were significantly different among tendons and were substantially greater than the effects of donor characteristics. Significant effects of donor sex, age, and height were limited to specific tendons: Achilles tendon, tibialis posterior, and tibialis anterior. All other tendons were unaffected. The Achilles tendon was most influenced by donor variables: greater CSA in men (β = 15.45 mm2 ; Šidák adjusted P < .0001), decreased maximum load with each year of increased age (β = -17.20 N per year; adjusted P = .0253), and increased CSA (β = 1.92 mm2 per inch; adjusted P < .0001) and maximum load (β = 86.40 N per inch; adjusted P < .0001) with each inch of increased height.
CONCLUSION: Mechanical properties vary significantly across different human tendons. The effects of donor age, sex, and height are relatively small, are limited to specific tendons, and affect different tendons uniquely. The findings indicate that age negatively affected only the Achilles tendon (maximum load) and challenge the exclusion of donors aged >65 years across all tendon grafts.
CLINICAL RELEVANCE: The findings support including a broader range of tendons for use as allografts for anterior cruciate ligament reconstruction and reviewing the current exclusion criterion of donors aged >65 years.
Full text links
Related Resources
Trending Papers
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of Clinical Monitoring and Computing 2024 April 31
SGLT2 Inhibitors in Kidney Diseases-A Narrative Review.International Journal of Molecular Sciences 2024 May 2
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app