The Impact of Prostate Volume on Prostate Cancer Detection: Comparing Magnetic Resonance Imaging with Transrectal Ultrasound in Biopsy-naïve Men.
European urology open science. 2024 June
BACKGROUND AND OBJECTIVE: This study aimed to determine the difference in prostate volume (PV) derived from transrectal ultrasound (TRUS) and multiparametric magnetic resonance imaging (mpMRI), and to further investigate the role of TRUS prostate-specific antigen density (PSAD) and mpMRI-PSAD in prostate cancer (PCa) detection in biopsy-naïve men.
METHODS: Patients who underwent an initial prostate biopsy within 3 mo after mpMRI between January 2016 and December 2021 were analyzed retrospectively. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of both TRUS-PSAD and mpMRI-PSAD for PCa detection were calculated and compared. The Pearson correlation coefficient, Bland-Altman plot, and receiver operating characteristic curve were also utilized to explore the interests of this study.
KEY FINDINGS AND LIMITATIONS: The median prostate-specific antigen level of 875 patients was 9.79 (interquartile range [IQR]: 7.09-13.50) ng/ml. The median mpMRI-PV and TRUS-PV were 41.92 (IQR: 29.29-60.73) and 41.04 (IQR: 29.24-57.27) ml, respectively, demonstrating a strong linear correlation ( r = 0.831, 95% confidence interval: 0.809, 0.850; p < 0.01) and sufficient agreement. No significant difference was observed in terms of the sensitivity, specificity, PPV, and NPV between TRUS-PSAD and mpMRI-PSAD for any PCa and clinically significant PCa (csPCa) detection. The overall discriminative ability of TRUS-PSAD for detecting PCa or non-PCa, as well as csPCa and non-csPCa, was comparable with that of mpMRI-PSAD, and similar results were also observed in the subsequent analysis stratified by mpMRI-PV quartiles, prostate-specific antigen level, and age. The limitations include the retrospective and single-center nature and a lack of follow-up information.
CONCLUSIONS AND CLINICAL IMPLICATIONS: TRUS-PV and MRI-PV exhibited a strong linear correlation and reached sufficient agreement. The efficiency of TRUS-PSAD and mpMRI-PSAD for PCa detection was comparable. TRUS could be used for PV estimation and dynamic monitoring of PSAD, and TRUS-PSAD could effectively guide clinical decision-making and optimize diagnostic strategies.
PATIENT SUMMARY: In this work, prostate volume (PV) derived from transrectal ultrasound (TRUS) exhibited a strong linear correlation with the PV derived from multiparametric magnetic resonance imaging (mpMRI). The efficiency of TRUS prostate-specific antigen density (PSAD) and mpMRI-PSAD for the detection of prostate cancer was comparable. TRUS could be used for PV estimation and TRUS-PSAD could help in clinical decision-making and optimizing diagnostic strategies.
METHODS: Patients who underwent an initial prostate biopsy within 3 mo after mpMRI between January 2016 and December 2021 were analyzed retrospectively. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of both TRUS-PSAD and mpMRI-PSAD for PCa detection were calculated and compared. The Pearson correlation coefficient, Bland-Altman plot, and receiver operating characteristic curve were also utilized to explore the interests of this study.
KEY FINDINGS AND LIMITATIONS: The median prostate-specific antigen level of 875 patients was 9.79 (interquartile range [IQR]: 7.09-13.50) ng/ml. The median mpMRI-PV and TRUS-PV were 41.92 (IQR: 29.29-60.73) and 41.04 (IQR: 29.24-57.27) ml, respectively, demonstrating a strong linear correlation ( r = 0.831, 95% confidence interval: 0.809, 0.850; p < 0.01) and sufficient agreement. No significant difference was observed in terms of the sensitivity, specificity, PPV, and NPV between TRUS-PSAD and mpMRI-PSAD for any PCa and clinically significant PCa (csPCa) detection. The overall discriminative ability of TRUS-PSAD for detecting PCa or non-PCa, as well as csPCa and non-csPCa, was comparable with that of mpMRI-PSAD, and similar results were also observed in the subsequent analysis stratified by mpMRI-PV quartiles, prostate-specific antigen level, and age. The limitations include the retrospective and single-center nature and a lack of follow-up information.
CONCLUSIONS AND CLINICAL IMPLICATIONS: TRUS-PV and MRI-PV exhibited a strong linear correlation and reached sufficient agreement. The efficiency of TRUS-PSAD and mpMRI-PSAD for PCa detection was comparable. TRUS could be used for PV estimation and dynamic monitoring of PSAD, and TRUS-PSAD could effectively guide clinical decision-making and optimize diagnostic strategies.
PATIENT SUMMARY: In this work, prostate volume (PV) derived from transrectal ultrasound (TRUS) exhibited a strong linear correlation with the PV derived from multiparametric magnetic resonance imaging (mpMRI). The efficiency of TRUS prostate-specific antigen density (PSAD) and mpMRI-PSAD for the detection of prostate cancer was comparable. TRUS could be used for PV estimation and TRUS-PSAD could help in clinical decision-making and optimizing diagnostic strategies.
Full text links
Related Resources
Trending Papers
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of Clinical Monitoring and Computing 2024 April 31
SGLT2 Inhibitors in Kidney Diseases-A Narrative Review.International Journal of Molecular Sciences 2024 May 2
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app