Add like
Add dislike
Add to saved papers

Asymmetric gap balancing improves knee kinematic following primary total knee arthroplasty.

Arthroplasty. 2024 April 26
PURPOSE: The purpose of this study was to demonstrate closer-to-normal knee kinematics following primary total knee arthroplasty (TKA) performed establishing asymmetric gap balancing intraoperatively.

MATERIAL AND METHOD: Two age-, sex-, BMI-matched groups of patients underwent medially stabilized TKA because of isolated knee disease. Group A (12 patients) underwent "unrestricted" kinematic alignment (uKA) according to Howell while group B (15 patients) received robot-assisted "simplified" KA (sKA) with an alignment goal (Hip-Knee-Ankle axis-HKA) ± 5° respect to the mechanical axis. Intraoperatively, in group B, the flexion gap at 90° was first set at an average of 1.5 mm (0-5 mm; SD 4.4 mm) tighter in the medial compartment with respect to the lateral; in the same way, the extension gap was then set at an average of 2.0 mm (0-4.5 mm; SD 3.1 mm) tighter in the medial compartment with respect to the lateral. All patients, including a non-arthritic cohort (group C: 5 controls) underwent gait analysis using an instrumented treadmill (WalkerView-WV) equipped with an instrumented belt armed with a 3D video camera. The WV software evaluated multiple spatiotemporal and kinematic parameters, including: (1) contact time (s); (2) knee ROM during gait cycle; (3) step length percentage with respect to total gait (%) and pure step length (cm). Statistical analyses included t-Test and ANOVA and were conducted by using SPSS.

RESULTS: At the final FU, significant differences were noted during gait between the two TKA groups (uKA-sKA) and the controls. Both TKA groups showed superior mean contact time on the surgical knee (uKA 1 s; sKA 0.97 s) as compared to the controls (0.72 s) (P = 0.002) while no differences were found between them (P = 0.11). TKA groups showed a lower, maximum ROM in the surgical knee (mean uKA 36º; mean sKA 49º) relative to the controls (mean 57º) (P < 0.05) but a statistical difference was found between them (P = 0.003). Both TKA groups showed a higher step length percentage with respect to the total gait and a shorter step length on the surgical side (uKA: mean 8.28% and mean step length 35.5 cm; sKA: mean 8.38% and mean step length 34.6 cm) in comparison to the controls (mean 3.38%; mean step length 71.4 cm) (P < 0.05) while no statistical differences were found between them.

CONCLUSION: To our knowledge, this was the first study to exhibit the kinematic advantages of a slightly asymmetric gap balancing during KA TKA. Combining a medially-stabilized implant design and a surgical technique aiming to obtain a tighter medial compartment represents a promising approach to improve outcomes after TKA.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app