Add like
Add dislike
Add to saved papers

Associations between ultra-distal forearm bone mineral density and incident fracture in women.

UNLABELLED: Bone mineral density measured at the ultra-distal forearm site was associated with any fracture, as well as distal radius fracture in women from a longitudinal cohort study.

PURPOSE: Femoral neck (BMDhip ) and lumbar spine (BMDspine ) bone mineral density (BMD) are routinely used to assess fracture risk. More data are needed to understand how ultra-distal forearm BMD (BMDUDforearm ) may assist fracture prediction.

METHODS: Using a Lunar DPX-L, Geelong Osteoporosis Study women (n = 1026), aged 40-90 years, had BMD measured. Incident low-trauma fractures were radiologically verified. Using Cox proportional hazard models, hazard ratios (HR) were calculated for BMDUDforearm as a continuous variable (expressed as a one-unit decrease in T-score) and a categorical variable (normal/osteopenia/osteoporosis). Areas under receiver operating characteristics (AUROC) curves were calculated. Analyses were conducted for any fracture and distal radius fractures.

RESULTS: During 14,270 person-years of follow-up, there were 318 fractures (85 distal radius). In adjusted models, continuous BMDUDforearm was associated with any (HR 1.26;95%CI 1.15-1.39) and distal radius fractures (HR 1.59;95%CI 1.38-1.83). AUROCs for continuous BMDUDforearm , 33% forearm(BMD33%forearm ), BMDhip , BMDspine , and FRAX without BMD were similar for any fracture (p > 0.05). For distal radius fracture, the AUROC for BMDUDforearm was higher than other sites and FRAX (p < 0.05). In adjusted models, those with osteoporosis had a higher likelihood of any fracture (HR 2.12; 95%CI 1.50-2.98). For distal radius fractures, both osteopenia and osteoporosis had a higher risk (HR 4.31; 95%CI 2.59-7.15 and 4.81; 95%CI 2.70-8.58). AUROCs for any fracture were similar for categorical BMD at all sites but lower for FRAX (p < 0.05). For distal radius fractures, the AUROC for BMDUDforearm , was higher than other sites and FRAX (p < 0.05).

CONCLUSION: Ultra-distal forearm BMD may aid risk assessments for any distal radius fractures.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app