Renal function-adapted D-dimer cutoffs in combination with a clinical prediction rule to exclude pulmonary embolism in patients presenting to the emergency department.

D-dimer levels significantly increase with declining renal function and hence, renal function-adjusted D-dimer cutoffs to rule out pulmonary embolism were suggested. Aim of this study was to "post hoc" validate previously defined renal function-adjusted D-dimer levels to safely rule out pulmonary embolism in patients presenting to the emergency department. In this retrospective, observational analysis, all patients with low to intermediate pre-test probability receiving D-dimer measurement and computed tomography angiography (CTA) to rule out pulmonary embolism between January 2017 and December 2020 were included. Previously defined renal function-adjusted D-dimer cutoffs (1306 µg/l for moderate and 1663 µg/l for severe renal function impairment) were applied to determine sensitivity, specificity, negative and positive predictive values. One thousand, three hundred sixty-nine patients were included of which 229 (17%) were diagnosed with pulmonary embolism. The estimated glomerular filtration rate (eGFR) was ≥ 60 ml/min in 1079 (79%), 30-59 ml/min in 266 (19%) and < 30 ml/min in 24 (2%) patients. Only three patients (1.1%) with an eGFR < 60 ml/min had a D-dimer level < 500 µg/l. There was a significant correlation between D-dimer and eGFR (R = - 0.159, p < 0.001). Calculated on the standard D-dimer cutoff value of 500 µg/l, sensitivity of D-dimer testing was 97% for patients with an eGFR ≥ 60 ml/min and 100% for those with 30-60 ml/min, while specificity decreased in patients with renal function impairment. A negative predictive value of 0.99 as a premise to safely rule out pulmonary embolism was achieved by applying a D-dimer cutoff of 1480 µg/l for eGFR 30-59 ml/min and 1351 µg/l for eGFR < 30 ml/min. The findings of this study underline that application of renal function-adapted D-dimer levels in combination with a clinical prediction rule appears feasible to rule out pulmonary embolism. Out of the current dataset, renal function-adjusted D-dimer cutoffs to rule out pulmonary embolism were slightly different compared to previously defined cutoffs. Further studies on a larger scale are needed to validate possible renal function-adjusted D-dimer cutoffs.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app