Completed FDA feasibility trial of surgically placed temporary diaphragm pacing electrodes: A promising option to prevent and treat respiratory failure.
American Journal of Surgery 2018 March
BACKGROUND: Etiologies contributing to failure to wean from mechanical ventilation (MV) are multiple, resulting in morbid and costly outcomes. Diaphragm pacing (DP) is used in spinal cord injury to replace MV. Temporary DP could be utilized in acute respiratory failure to reduce MV.
METHODS: A prospective FDA feasibility trial evaluated temporary DP electrodes implanted in each hemi-diaphragm during a subject's primary procedure. Objectives included: ability to provide ventilation, stability analysis with diaphragm electromyography, and adverse event monitoring.
RESULTS: Twelve patients underwent successful implantation via median sternotomy, laparoscopy or laparotomy. Electrode stimulation exceeded ideal tidal volumes by an average of 37% (0%-95%) confirming ability to prevent atrophy. Daily electromyography confirmed stability of placement and was useful in evaluating hypoventilation. There were no complications and all 48 study electrodes remained intact until complete removal.
CONCLUSION: This trial demonstrates ease of placement, removal, functionality and safety of temporary DP electrodes which therapeutically decreases diaphragm atrophy.
METHODS: A prospective FDA feasibility trial evaluated temporary DP electrodes implanted in each hemi-diaphragm during a subject's primary procedure. Objectives included: ability to provide ventilation, stability analysis with diaphragm electromyography, and adverse event monitoring.
RESULTS: Twelve patients underwent successful implantation via median sternotomy, laparoscopy or laparotomy. Electrode stimulation exceeded ideal tidal volumes by an average of 37% (0%-95%) confirming ability to prevent atrophy. Daily electromyography confirmed stability of placement and was useful in evaluating hypoventilation. There were no complications and all 48 study electrodes remained intact until complete removal.
CONCLUSION: This trial demonstrates ease of placement, removal, functionality and safety of temporary DP electrodes which therapeutically decreases diaphragm atrophy.
Full text links
Related Resources
Trending Papers
Review article: Recent advances in ascites and acute kidney injury management in cirrhosis.Alimentary Pharmacology & Therapeutics 2024 March 26
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app