We have located links that may give you full text access.
Graft Diameter as a Predictor for Revision Anterior Cruciate Ligament Reconstruction and KOOS and EQ-5D Values: A Cohort Study From the Swedish National Knee Ligament Register Based on 2240 Patients.
American Journal of Sports Medicine 2017 July
BACKGROUND: Anterior cruciate ligament (ACL) reconstruction (ACLR) using a hamstring tendon (HT) autograft is an effective and widespread method. Recent studies have identified a relationship between the graft diameter and revision ACLR.
PURPOSE: To evaluate the influence of the graft diameter on revision ACLR and patient-reported outcomes in patients undergoing primary ACLR using HT autografts.
STUDY DESIGN: Cohort study; Level of evidence, 2.
METHODS: A prospective cohort study was conducted using the Swedish National Knee Ligament Register (SNKLR) involving all patients undergoing primary ACLR using HT autografts. Patients with graft failure who needed revision surgery (cases) were compared with patients not undergoing revision surgery (controls). The control group was matched for sex, age, and graft fixation method in a 3:1 ratio. Conditional logistic regression was performed to produce odds ratios and 95% CIs. Univariate linear regression analyses were performed for patient-related outcomes. The Knee injury and Osteoarthritis Outcome Score (KOOS) and EuroQol 5 dimensions questionnaire (EQ-5D) values were obtained.
RESULTS: A total of 2240 patients were included in which there were 560 cases and 1680 controls. No significant differences between the cases and controls were found for sex (52.9% male), mean age (21.7 years), and femoral and tibial fixation. The mean graft diameter for the cases was 8.0 ± 0.74 mm and for the controls was 8.1 ± 0.76 mm. In the present cohort, the likelihood of revision surgery for every 0.5-mm increase in the HT autograft diameter between 7.0 and 10.0 mm was 0.86 (95% CI, 0.75-0.99; P = .03). Univariate linear regression analysis found no significant regression coefficient for the change in KOOS or EQ-5D values.
CONCLUSION: In a large cohort of patients after primary ACLR with HT autografts, an increase in the graft diameter between 7.0 and 10.0 mm resulted in a 0.86 times lower likelihood of revision surgery with every 0.5-mm increase. This study provides further evidence of the importance of the HT autograft size in intraoperative decision making.
PURPOSE: To evaluate the influence of the graft diameter on revision ACLR and patient-reported outcomes in patients undergoing primary ACLR using HT autografts.
STUDY DESIGN: Cohort study; Level of evidence, 2.
METHODS: A prospective cohort study was conducted using the Swedish National Knee Ligament Register (SNKLR) involving all patients undergoing primary ACLR using HT autografts. Patients with graft failure who needed revision surgery (cases) were compared with patients not undergoing revision surgery (controls). The control group was matched for sex, age, and graft fixation method in a 3:1 ratio. Conditional logistic regression was performed to produce odds ratios and 95% CIs. Univariate linear regression analyses were performed for patient-related outcomes. The Knee injury and Osteoarthritis Outcome Score (KOOS) and EuroQol 5 dimensions questionnaire (EQ-5D) values were obtained.
RESULTS: A total of 2240 patients were included in which there were 560 cases and 1680 controls. No significant differences between the cases and controls were found for sex (52.9% male), mean age (21.7 years), and femoral and tibial fixation. The mean graft diameter for the cases was 8.0 ± 0.74 mm and for the controls was 8.1 ± 0.76 mm. In the present cohort, the likelihood of revision surgery for every 0.5-mm increase in the HT autograft diameter between 7.0 and 10.0 mm was 0.86 (95% CI, 0.75-0.99; P = .03). Univariate linear regression analysis found no significant regression coefficient for the change in KOOS or EQ-5D values.
CONCLUSION: In a large cohort of patients after primary ACLR with HT autografts, an increase in the graft diameter between 7.0 and 10.0 mm resulted in a 0.86 times lower likelihood of revision surgery with every 0.5-mm increase. This study provides further evidence of the importance of the HT autograft size in intraoperative decision making.
Full text links
Related Resources
Trending Papers
Review article: Recent advances in ascites and acute kidney injury management in cirrhosis.Alimentary Pharmacology & Therapeutics 2024 March 26
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app