We have located links that may give you full text access.
Impact of a contouring atlas on radiographer inter-observer variation in male pelvis radiotherapy.
Journal of Medical Imaging and Radiation Sciences 2024 April 12
PURPOSE/OBJECTIVE: To determine the impact of a MR-based contouring atlas for male pelvis radiotherapy delineation on inter-observer variation to support radiographer led real-time magnetic resonance image guided adaptive radiotherapy (MRgART).
MATERIAL/METHODS: Eight RTTs contoured 25 MR images in the Monaco treatment planning system (Monaco 5.40.01), from 5 patients. The prostate, seminal vesicles, bladder, and rectum were delineated before and after the introduction of an atlas developed through multi-disciplinary consensus. Inter-observer contour variations (volume), time to contour and observer contouring confidence were determined at both time-points using a 5-point Likert scale. Descriptive statistics were used to analyse both continuous and categorical variables. Dice similarity coefficient (DSC), Dice-Jaccard coefficient (DJC) and Hausdorff distance were used to calculate similarity between observers.
RESULTS: Although variation in volume definition decreased for all structures among all observers post intervention, the change was not statistically significant. DSC and DJC measurements remained consistent following the introduction of the atlas for all observers. The highest similarity was found in the bladder and prostate whilst the lowest was the seminal vesicles. The mean contouring time for all observers was reduced by 50% following the introduction of the atlas (53 to 27 minutes, p=0.01). For all structures across all observers, the mean contouring confidence increased significantly from 2.3 to 3.5 out of 5 (p=0.02).
CONCLUSION: Although no significant improvements were observed in contour variation amongst observers, the introduction of the consensus-based contouring atlas improved contouring confidence and speed; key factors for a real-time RTT-led MRgART.
MATERIAL/METHODS: Eight RTTs contoured 25 MR images in the Monaco treatment planning system (Monaco 5.40.01), from 5 patients. The prostate, seminal vesicles, bladder, and rectum were delineated before and after the introduction of an atlas developed through multi-disciplinary consensus. Inter-observer contour variations (volume), time to contour and observer contouring confidence were determined at both time-points using a 5-point Likert scale. Descriptive statistics were used to analyse both continuous and categorical variables. Dice similarity coefficient (DSC), Dice-Jaccard coefficient (DJC) and Hausdorff distance were used to calculate similarity between observers.
RESULTS: Although variation in volume definition decreased for all structures among all observers post intervention, the change was not statistically significant. DSC and DJC measurements remained consistent following the introduction of the atlas for all observers. The highest similarity was found in the bladder and prostate whilst the lowest was the seminal vesicles. The mean contouring time for all observers was reduced by 50% following the introduction of the atlas (53 to 27 minutes, p=0.01). For all structures across all observers, the mean contouring confidence increased significantly from 2.3 to 3.5 out of 5 (p=0.02).
CONCLUSION: Although no significant improvements were observed in contour variation amongst observers, the introduction of the consensus-based contouring atlas improved contouring confidence and speed; key factors for a real-time RTT-led MRgART.
Full text links
Related Resources
Trending Papers
Renin-Angiotensin-Aldosterone System: From History to Practice of a Secular Topic.International Journal of Molecular Sciences 2024 April 5
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app