Sirolimus-Coated Balloon in an All-Comer Population of Coronary Artery Disease Patients: The EASTBOURNE Prospective Registry.

BACKGROUND: Drug-coated balloons (DCB) represent 1 of the most promising innovations in interventional cardiology and may represent a valid alternative to drug-eluting stents. Currently, some sirolimus-coated balloons (SCB) are being investigated for several coronary artery disease applications.

OBJECTIVES: This study sought to understand the role of a novel SCB for the treatment of coronary artery disease.

METHODS: EASTBOURNE (All-Comers Sirolimus-Coated Balloon European Registry) is a prospective, multicenter, investigator-driven clinical study that enrolled real-world patients treated with SCB. Primary endpoint was target lesion revascularization (TLR) at 12 months. Secondary endpoints were procedural success, myocardial infarction (MI), all-cause death, and major adverse clinical events (a composite of death, MI, and TLR). All adverse events were censored and adjudicated by an independent clinical events committee.

RESULTS: A total population of 2,123 patients (2,440 lesions) was enrolled at 38 study centers in Europe and Asia. The average age was 66.6 ± 11.3 years, and diabetic patients were 41.5%. De novo lesions (small vessels) were 56%, in-stent restenosis (ISR) 44%, and bailout stenting occurred in 7.7% of the patients. After 12 months, TLR occurred in 5.9% of the lesions, major adverse clinical events in 9.9%, and spontaneous MI in 2.4% of the patients. The rates of cardiac/all-cause death were 1.5% and 2.5%, respectively. The primary outcome occurred more frequently in the ISR cohort (10.5% vs 2.0%; risk ratio: 1.90; 95% CI: 1.13-3.19). After multivariate Cox regression model, the main determinant for occurrence of the primary endpoint was ISR (OR: 5.5; 95% CI: 3.382-8.881).

CONCLUSIONS: EASTBOURNE, the largest DCB study in the coronary field, shows the safety and efficacy of a novel SCB in a broad population of coronary artery disease including small vessels and ISR patients at mid-term follow-up. (The All-Comers Sirolimus-Coated Balloon European Registry [EASTBOURNE]; NCT03085823).

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app