OBJECTIVE: To determine the effect of video and direct laryngoscopy on first-pass success rates for out-of-hospital orotracheal intubation.

METHODS: MEDLINE, Embase, and Cochrane databases were searched from inception to January 2023. Out-of-hospital studies comparing video and direct laryngoscopy on either first-pass or overall intubation success were included. A random effects meta-analysis was performed with a primary outcome of first-pass success stratified by clinician type and laryngoscope blade geometry. The secondary outcomes were overall intubation success stratified by clinician type, and intubation time. All hypotheses and subgroup analyses were determined a priori .

RESULTS: Twenty-five studies involving 35,489 intubations met inclusion criteria. Substantial heterogeneity (>75%) precluded reporting point estimates for nearly all analyses. For our primary outcome, video laryngoscopy was associated with improved first-pass success in 3/5 physician studies, 4/6 critical care paramedic/registered nurse studies, and 7/10 paramedic studies. Video laryngoscope devices with Macintosh blade geometry were associated with improved first-pass success in 7/10 studies, while devices with hyperangulated geometry were associated with improved first-pass success in 3/7 studies. Overall intubation success was greater with video laryngoscopy in 2/6 studies in the physician subgroup and 9/10 studies in the paramedic subgroup. Video laryngoscopy was not associated with overall intubation success among critical care paramedics/nurses (OR = 1.89, 0.96 to 3.72, I2 = 34%). Lastly, 4/5 studies found video laryngoscopy to be associated with longer intubation times.

CONCLUSIONS: We found substantial heterogeneity among out-of-hospital studies comparing video laryngoscopy to direct laryngoscopy on first-pass success, overall success, or intubation time. This heterogeneity was not explained with stratification by study design, clinician type, video laryngoscope blade geometry, or leave-one-out meta-analysis. A majority of studies showed that video laryngoscopy was associated with improved first pass success in all subgroups, but only for paramedics and not physicians when looking at overall success. This improvement was more common in studies that used Macintosh blades than those that used hyperangulated blades. Future research should explore the heterogeneity identified in our analysis with an emphasis on differences in training, clinical milieu, and specific video laryngoscope devices.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app