The feasibility of superparamagnetic iron oxide-enhanced magnetic resonance imaging for assessing liver lesions in patients with contraindications for iodine CT contrast media or gadolinium-based MR contrast media: a retrospective case-control study.

Background: The detection and characterization of liver lesions are problematic in patients with bronchial asthma, renal dysfunction, or a history of allergy to gadolinium-based magnetic resonance contrast media or iodine-computed tomography contrast media because these contrast media cannot be used. Hence, the information on the lesion vascularity cannot be obtained. Therefore, this retrospective case-control study evaluated the feasibility of superparamagnetic iron oxide (SPIO) in patients with one or more of these contraindications who underwent SPIO-enhanced magnetic resonance imaging for the assessment of liver lesions.

Methods: Twenty-six patients with a total of 48 lesions were analyzed. SPIO was used in the case of all patients because each patient had at least one reason not to use iodine contrast or gadolinium-based contrast media. Additionally, all patients were subjected to the perfusion study. A total volume of 1.3 mL of SPIO was injected via the cubital vein at a rate of 3 mL per second, followed by 40 mL saline at the same speed. The scanning of the perfusion study was started 4 s after the beginning of superparamagnetic iron oxide injection and scanning took 50 s. Two radiologists independently evaluated whether the lesion was malignant or benign. Receiver operating characteristic analysis (ROC) was performed to determine the additional benefit of the perfusion study.

Results: There were no adverse effects associated with SPIO. The area under the curve (AUC) value without perfusion study for observers 1 and 2 were 0.473 (P=0.794, 95% CI: 0.275-0.672) and 0.602 (P=0.305, 95% CI: 0.407-0.798), respectively, whereas the Az values with perfusion study for observers 1 and 2 were 0.782 (P=0.011, 95% CI: 0.565-0.998) and 0.784 (P=0.004, 95% CI: 0.591-0.977), respectively. Az value became significantly better when the perfusion study has added (P=0.001 and 0.012 by observers 1 and 2).

Conclusions: SPIO can be used safely in patients with bronchial asthma, renal dysfunction, or a history of contrast media allergy. Furthermore, the diagnostic accuracy of SPIO was acceptable.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app