Add like
Add dislike
Add to saved papers

A two-year comparison of reverse total shoulder arthroplasty mini-humeral tray and augmented mini-glenoid baseplate implants vs. standard implants.

BACKGROUND: Patients who undergo reverse total shoulder arthroplasty (RTSA) are getting younger with greater function expectations. This retrospective, longitudinal study of prospectively collected data compared perceived shoulder function and strength, active shoulder mobility, radiographic evidence of scapular notching, and implant survival over the initial 2-years post-RTSA among patient groups who received either standard central fixation point liner and glenoid baseplate implants, or lower size profile mini-humeral tray with offset trunnion options and mini-augmented glenoid baseplate implants.

MATERIALS AND METHODS: Patients who underwent primary RTSA using standard central fixation point liner and glenoid baseplate implants (Group 1, n = 180) were compared with patients who underwent primary RTSA using lower size profile mini-humeral tray with offset trunnion options and mini-augmented glenoid baseplate implants (Group 2, n = 53) for active shoulder mobility, American Shoulder and Elbow Surgeons (ASES) score, perceived ability to lift 10 lbs (4.5 kg) overhead, radiographic evidence of scapular notching, and implant survival. Data was collected pre-surgery, 6-weeks, 6-months, 1-year, and 2-years post-RTSA (p ≤ 0.05).

RESULTS: More Group 2 patients had more complex B or C Walch glenoid morphology, while Group 1 had more A1 or A2 types (p ≤ 0.001). Group 2 had greater active shoulder flexion at 6-months, 1-year, and 2-years (p ≤ 0.018) and external rotation (in adduction) at 6-months and 2-years (p ≤ 0.004) compared to Group 1, with higher ASES scores at 6-months and 2-years (p ≤ 0.026) (with small-to-medium effect sizes), and with more patients meeting or exceeding the minimal clinically important difference (MCID) at 2-years (p = 0.045) and patient acceptable symptomatic state (PASS) levels at 6-months, 1-year and 2-years (p ≤ 0.045). Scapular notching was identified in six of 53 (11.3%) Group 2 patients and in 32 of 180 (17.7%) Group 1 patients. Group 1 patients had more grade 2 or greater scapular notching grades compared to Group 2 (p = 0.04). Implant survival was comparable with Group 1 = eight of 180 (4.4%) and Group 2 = 1 of 53 (1.9%) of patients requiring removal for 95.6% and 98.1% implant survival, respectively.

CONCLUSION: Limited scapular notching and excellent implant survival was observed in both groups. Despite including individuals with more complex glenoid deficiency, patients receiving the lower size profile implants generally displayed better active shoulder mobility and perceived shoulder function compared to those who received standard implants. These patients also more frequently met or exceeded the MCID by 2-years post-RTSA and PASS levels by 6-months, 1-year, and 2-years post-RTSA, with lower scapular notching grades.

LEVEL OF EVIDENCE: Retrospective comparative study.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app