Diagnostic accuracy of pancreatic stone protein in patients with sepsis: a systematic review and meta-analysis.
BMC Infectious Diseases 2024 May 7
BACKGROUND: Sepsis is a common syndrome of multiorgan system dysfunction secondary to the dysregulated inflammatory response to infection. The role of pancreatic stone protein (PSP) in diagnosing sepsis has been investigated in previous studies. The meta-analysis aimed to comprehensively investigate the diagnostic value of PSP in identifying sepsis.
METHODS: PubMed, Web of Science, Embase, Cochrane Library, and China National Knowledge Infrastructure (CNKI), were systematically searched. Studies investigating the diagnostic performance of PSP were included. Pooled sensitivity, specificity, positive Likelihood Ratio (+ LR) and negative Likelihood Ratio (-LR), diagnostic odds ratio (DOR), and area under the curve (AUC) of summary receiver operating characteristic (SROC) were calculated.
RESULTS: The sensitivity of PSP was 0.88 (95% CI: 0.77-0.94), and the pooled specificity was 0.78 (95% CI: 0.65-0.87). Pooled + LR, -LR, and DOR were 4.1 (2.3, 7.3), 0.16 (0.07, 0.34), and 26 (7, 98). The AUC value for the SROC of PSP was 0.90 (0.87, 0.92). The pooled sensitivity, specificity, + LR and - LR, and DOR for PSP among neonates were 0.91 (95% CI: 0.84, 0.96), 0.66 (95% CI: 0.58, 0.74), 3.97 (95% CI: 0.53, 29.58), 0.13 (95% CI: 0.02, 1.00), and 31.27 (95% CI: 0.97, 1004.60).
CONCLUSIONS: This study indicates that PSP demonstrated favorable diagnostic accuracy in detecting sepsis. Well-designed studies are warranted to ascertain the value of PSP measurement to guide early empirical antibiotic treatment, particularly in neonates.
METHODS: PubMed, Web of Science, Embase, Cochrane Library, and China National Knowledge Infrastructure (CNKI), were systematically searched. Studies investigating the diagnostic performance of PSP were included. Pooled sensitivity, specificity, positive Likelihood Ratio (+ LR) and negative Likelihood Ratio (-LR), diagnostic odds ratio (DOR), and area under the curve (AUC) of summary receiver operating characteristic (SROC) were calculated.
RESULTS: The sensitivity of PSP was 0.88 (95% CI: 0.77-0.94), and the pooled specificity was 0.78 (95% CI: 0.65-0.87). Pooled + LR, -LR, and DOR were 4.1 (2.3, 7.3), 0.16 (0.07, 0.34), and 26 (7, 98). The AUC value for the SROC of PSP was 0.90 (0.87, 0.92). The pooled sensitivity, specificity, + LR and - LR, and DOR for PSP among neonates were 0.91 (95% CI: 0.84, 0.96), 0.66 (95% CI: 0.58, 0.74), 3.97 (95% CI: 0.53, 29.58), 0.13 (95% CI: 0.02, 1.00), and 31.27 (95% CI: 0.97, 1004.60).
CONCLUSIONS: This study indicates that PSP demonstrated favorable diagnostic accuracy in detecting sepsis. Well-designed studies are warranted to ascertain the value of PSP measurement to guide early empirical antibiotic treatment, particularly in neonates.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app