We have located links that may give you full text access.
Effects of a Long-Acting Diquafosol Ophthalmic Solution on the Ocular Surface, Tolerability, and Usability in Dry Eye Disease.
Advances in Therapy 2024 May 7
INTRODUCTION: This study aimed to investigate the tolerability of high-viscosity diquafosol tetrasodium (DQS) ophthalmic solution (DIQUAS LX; DQSLX) and examine its usability and effect on clinical findings in patients with dry eye disease (DED).
METHODS: This interventional retrospective study included 66 eyes of 66 patients with DED who switched from conventional DQS to DQSLX ophthalmic solution. Tear function assessments (tear film breakup time [BUT], keratoconjunctival vital staining [VS] score), evaluations of DED symptom relief, and a four-item usability questionnaire ("comfort upon instillation," "irritation upon instillation," "eye mucus discharge," "convenience of instillation frequency") assessed using a visual analog scale from 0 (worst) to 10 (best) were administered 4 weeks after switching to DQSLX. Factors associated with drug tolerability were assessed using multiple regression analysis.
RESULTS: The symptoms improved by 64.2% after switching to DQSLX. The BUT value, VS score, and the questionnaire items "comfort upon instillation" and "convenience of instillation frequency" were significantly improved after switching to DQSLX. DQSLX tolerability was reported as acceptable in 56 (84.8%) and unacceptable in 10 (15.2%) patients. Overall, DQSLX tolerability was significantly associated with "comfort upon instillation" and "convenience of instillation frequency" and tended to be associated with a VS score ≥ 1. DQSLX tolerability depended on symptom and VS score improvements and absence of excessive "eye mucus discharge" in patients with a VS score ≥ 1 (39 patients), but on "comfort upon instillation" and absence of excessive "eye mucus discharge" in patients with a VS score = 0 (27 patients).
CONCLUSION: The high-viscosity DQSLX ophthalmic solution was generally considered acceptable in the study population. However, drug tolerability seemingly differed between patients with DED with and without epithelial damage. The former were affected by improvements in symptoms and clinical findings, whereas the latter were affected by comfort upon instillation.
TRIAL REGISTRATION: University Hospital Medical Information Network identifier, UMIN000051390.
METHODS: This interventional retrospective study included 66 eyes of 66 patients with DED who switched from conventional DQS to DQSLX ophthalmic solution. Tear function assessments (tear film breakup time [BUT], keratoconjunctival vital staining [VS] score), evaluations of DED symptom relief, and a four-item usability questionnaire ("comfort upon instillation," "irritation upon instillation," "eye mucus discharge," "convenience of instillation frequency") assessed using a visual analog scale from 0 (worst) to 10 (best) were administered 4 weeks after switching to DQSLX. Factors associated with drug tolerability were assessed using multiple regression analysis.
RESULTS: The symptoms improved by 64.2% after switching to DQSLX. The BUT value, VS score, and the questionnaire items "comfort upon instillation" and "convenience of instillation frequency" were significantly improved after switching to DQSLX. DQSLX tolerability was reported as acceptable in 56 (84.8%) and unacceptable in 10 (15.2%) patients. Overall, DQSLX tolerability was significantly associated with "comfort upon instillation" and "convenience of instillation frequency" and tended to be associated with a VS score ≥ 1. DQSLX tolerability depended on symptom and VS score improvements and absence of excessive "eye mucus discharge" in patients with a VS score ≥ 1 (39 patients), but on "comfort upon instillation" and absence of excessive "eye mucus discharge" in patients with a VS score = 0 (27 patients).
CONCLUSION: The high-viscosity DQSLX ophthalmic solution was generally considered acceptable in the study population. However, drug tolerability seemingly differed between patients with DED with and without epithelial damage. The former were affected by improvements in symptoms and clinical findings, whereas the latter were affected by comfort upon instillation.
TRIAL REGISTRATION: University Hospital Medical Information Network identifier, UMIN000051390.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app