Reliability of a face scanner in measuring the vertical dimension of occlusion.

Journal of Dentistry 2024 April 27
OBJECTIVE: This study evaluated the reliability of a face scanner in measuring the vertical dimension of occlusion (VDO).

METHODS: Fully dentate volunteers (n=20; mean-age=30.0±10.7 years) were recruited. Clinical facial measurements were obtained using a digital caliper and a face scanner (Class 1 LASER, Obiscanner, Fifthingenium, Italy). The scans were imported into a mesh-processing software, and the distances were measured digitally. Measurements were obtained for each participant with the jaws positioned in maximal intercuspation (MI) and with increased vertical distances of 2, 4, and 6 mm. Vertical and horizontal measures were obtained using facial anatomical landmarks: Glabella (GL), Pronasale (PrN), Subnasale (SbN), inferior border of the right and left Alare, Labiale superius (Ls), right and left Cheilion (Ch), Soft Pogonion (SPg), right and left Tragus of the ear (Tr), for all selected vertical positions. Data analysis included intra-class correlation coefficient (ICC), pairwise comparison tests, Bland-Altman plots, and Passing-Bablok regression.

RESULTS: 120 VDO measurements (clinical=60, digital=60) were recorded by two independent evaluators. Mean differences between digital and clinical measurements ranged from 0.054±0.14mm to 0.203±0.13mm. All parameters were strongly correlated (r>0.93; p<0.001). ICC estimates revealed excellent reliability, and the measuring procedure yields the same results on repeated trials irrespective of the raters and measurement methods. Bland-Altman plots revealed a difference between digital and clinical measurements of 1.7% for the vertical measurements. Regression analysis revealed no significant proportional difference between the two methods, so both can be used interchangeably.

CONCLUSIONS: The findings of this study demonstrate that VDO can be measured accurately from face scans using 3D mesh-processing software and that even small changes in the VDO could be detected using the digital methods.

CLINICAL SIGNIFICANCE: Findings provide evidence about the reliability of a digital method for jaw relation registrations and may be applied towards incorporating this method into clinical workflows for CAD-CAM dentures.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app