Add like
Add dislike
Add to saved papers

Safety and efficacy of fluoroscopy-guided urethral catheterization in case of failed blind or cystoscopy-assisted urethral catheterization.

Scientific Reports 2024 April 25
This retrospective study evaluated the safety and efficacy of fluoroscopy-guided urethral catheterization in patients who failed blind or cystoscopy-assisted urethral catheterization. We utilized our institutional database between January 2011 and March 2023, and patients with failed blind or cystoscopy-assisted urethral catheterization and subsequent fluoroscopy-guided urethral catheterization were included. A 5-Fr catheter was inserted into the urethral orifice, and the retrograde urethrography (RGU) was acquired. Subsequently, the operator attempted to pass a hydrophilic guidewire to the urethra. If the guidewire and guiding catheter could be successfully passed into the bladder, but the urethral catheter failed pass due to urethral stricture, the operator determined either attempted again with a reduced catheter diameter or performed balloon dilation according to their preference. Finally, an appropriately sized urethral catheter was selected, and an endhole was created using an 18-gauge needle. The catheter was then inserted over the wire to position the tip in the bladder lumen and ballooned to secure it. We reviewed patients' medical histories, the presence of hematuria, and RGU to determine urethral abnormalities. Procedure-related data were assessed. Study enrolled a total of 179 fluoroscopy-guided urethral catheterizations from 149 patients (all males; mean age, 73.3 ± 13.3 years). A total of 225 urethral strictures were confirmed in 141 patients, while eight patients had no strictures. Urethral rupture was confirmed in 62 patients, and hematuria occurred in 34 patients after blind or cystoscopy-assisted urethral catheterization failed. Technical and clinical success rates were 100%, and procedure-related complications were observed in four patients (2.2%). The mean time from request to urethral catheter insertion was 129.7 ± 127.8 min. The mean total fluoroscopy time was 3.5 ± 2.5 min and the mean total DAP was 25.4 ± 25.1 Gy cm2 . Balloon dilation was performed in 77 patients. Total procedure time was 9.2 ± 7.6 min, and the mean procedure time without balloon dilation was 7.1 ± 5.7 min. Fluoroscopy-guided urethral catheterization is a safe and efficient alternative in patients where blind or cystoscopy-assisted urethral catheterization has failed or when cystoscopy-urethral catheterization cannot be performed.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app