Add like
Add dislike
Add to saved papers

Efficacy of hydroxypropyl-guar drops in improving tear film index and ocular surface dynamics using two treatment methods under a controlled desiccating environment.

AIM: This study aimed to assess the efficacy of hp-guar eye drops on tear film index and ocular surface dynamics under desiccating conditions using protection and relief treatment modalities.

METHODOLOGY: The 12 normal, non-dry eye participants were subjected to adverse environmental conditions using a Controlled Environment Chamber (CEC) where the relative humidity (RH) was 5% and the ambient temperature was 21 °C. The participants were screened for ocular symptoms, tear osmolarity, ocular surface temperature (OST), tear production using the Ocular Surface Disease Index questionnaire (OSDI), OcuSense TearLab Osmometer, FLIR System ThermaCAM P620, and Schirmer strips. Tear production was calculated by the Tear Function Index test (TFI).

RESULTS: The mean tear film osmolarity decreased significantly from 296 mOsm/L at 40% RH to 285 mOsm/L at 5% RH (p = 0.01). Conflicting responses were seen for osmolarity in protection and relief. Mean tear osmolarity was significantly higher in the protection method in comparison to the relief method (p = 0.005). The mean TFI increased from 557 at 40% to 854 at 5% (p = 0.02). A significant increase in TFI was observed in the relief method in comparison with both 40% (p = 0.001) and 5% (p = 0.04). In the relief method, the mean TFI score went up to 1139 when hp-guar was installed. A significant improvement in ocular comfort was experienced in both the protection (p = 0.041) and relief (p = 0.010) methods at 5% RH. The instillation of hp-guar drops in the relief method resulted in a significant reduction in OST. The mean OST dropped to 33.01 ºC, significantly lower than the recorded OST for both normal (p = 0.040) and dry (p = 0.014) environmental conditions.

CONCLUSION: Hp-guar drops significantly improve tear film parameters under a desiccating environment, however, tear film parameters respond differently to the management modalities. In the protection method, tear film osmolarity was protected against a dry environment, while in the relief mode, an improvement in tear production and a decrease in ocular surface temperature were seen. Hp-guar performance could be maximized for the management of exposure to adverse environments by using a treatment protocol that targets the most affected parameters in each group of patients. Using CEC has the potential to provide researchers with a readily available method to evaluate the efficiency of tear supplementation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app