Add like
Add dislike
Add to saved papers

Impact of osteoporosis and Cement-Augmented fusion on adjacent spinal levels Post-Fusion Surgery: Patient-Specific finite element analysis.

Cement-augmentation is a technique commonly used during posterior lumbar instrumented fusion (PLIF) to reinforce compromised osteoporotic vertebral bone, minimize the risk of loosening screws, enhance stability, and improve overall surgical outcomes. In this study, we introduce a novel segmented vertebral body regional modeling approach to investigate the effects of osteoporosis and cement-augmented lumbar fusion on disc biomechanics at spinal levels adjacent to the fused vertebrae. Using our previously validated personalized-poroelastic-osteoligamentous FE model of the spine, fusion was simulated at L4-L5, and the biomechanics of adjacent levels were studied for 30 patients (non-osteoporotic patients (N = 15), osteoporotic patients (N = 15)). PLIF models, with and without cement-augmentation, were developed and compared after an 8 h-rest period (200 N), following a 16 h-cyclic compressive loading of 500-1000 N (40 and 20 min, respectively). Movement in different directions (flexion/ extension/ lateral bending/ axial rotation) was simulated using 10Nm moment before and after cyclic loading. The material mapping algorithm was validated by comparing the results of voxel-based and parametric models. The FE cement-augmented models, subject to daily activity loading, demonstrated significant differences in disc height loss and fluid loss as compared to non-cemented models. The calculated axial stress and fiber strain values were also significantly higher for these models. This work demonstrates that although osteoporosis does not significantly alter the time-dependent characteristics of adjacent IVDs post-surgery, cement-augmentation increases the risk of adjacent segment disease (ASD) incidence. A holistic understanding of the trade-offs and long-term complex interplay between structural reinforcement modalities, including cement augmentation, and altered biomechanics warrants further investigation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app