Redefining Radiation Metrics: Evaluating Actual Doses in Computed Tomography Scans.

Biomedicines 2024 March 8
BACKGROUND: Computed tomography (CT) contributes significantly to the collective dose from medical sources, raising concerns about potential health risks. However, existing radiation dose estimation tools, such as volume computed tomography dose index (CTDIvol), dose-length product (DLP), effective dose (ED), and size-specific dose estimate (SSDE), have limitations in accurately reflecting patient exposure. This study introduces a new parameter, size-specific dose-length product (DLPss), aiming to enhance the precision of radiation dose estimation in real-life scenarios.

METHODS: A retrospective analysis of 134 chest CT studies was conducted. Relationships between CTDIvol and anthropometric parameters were examined, and SSDE was calculated based on effective diameter. Additionally, the novel parameter, DLPss, was introduced, considering scan length and cross-sectional dimensions.

RESULTS: Analysis reveals variations in scan length, effective diameter, and CTDIvol between genders. Strong correlations were observed between CTDIvol and effective diameter, particularly in men. The average CTDIvol for the entire group was 7.83 ± 2.92 mGy, with statistically significant differences between women (7.38 ± 3.23 mGy) and men (8.30 ± 2.49 mGy). SSDE values showed significant gender differences, with men exhibiting higher values. The average SSDE values for women and men were 9.15 ± 2.5 mGy and 9.6 ± 2.09 mGy, respectively, with a statistically significant difference ( p = 0.03). The newly introduced DLPss values ranged around 343.90 ± 81.66 mGy·cm for the entire group, with statistically significant differences between women (323.53 ± 78.69 mGy·cm) and men (364.89 ± 79.87 mGy·cm) ( p < 0.05), providing a comprehensive assessment of total radiation dose.

CONCLUSION: The study highlights the need for accurate radiation dose estimation, emphasizing the impact of CT examination parameters on dose variability. The proposed DLPss parameter offers a promising approach to enhancing precision in assessing radiation risk during CT scans. Further research is warranted to explore additional parameters for a comprehensive understanding of radiation exposure and to optimize imaging protocols for patient safety.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app