Add like
Add dislike
Add to saved papers

Sensitivity and specificity of the new Bio-Rad HIV screening test, Access HIV combo V2.

UNLABELLED: Diagnosing of human immunodeficiency virus (HIV) types 1 and 2 requires a screening with a highly sensitive and specific enzyme immunoassay and a low detection limit for the HIV-1 p24 antigen to minimize the diagnostic window. The objective of the study was to determine the sensitivity, specificity, and p24 limit of detection of the Access HIV combo V2 assay. Retrospective part of sensitivity: 452 HIV-1 positive samples from 403 chronic (9 different HIV-1 group M subtypes, 22 different HIV-1 group M CRFs, and 3 HIV-1 group O), 49 primary HIV-1 infections, 103 HIV-2 positive samples assessed at Pitié-Salpêtrière Hospital, 600 untyped HIV-1, 10 subtype-D, and 159 untyped HIV-2 samples assessed in Bio-Rad Laboratories. Prospective part of clinical specificity: all consecutive samples in two blood donor facilities and Pitié-Salpêtrière (6,570 patients) tested with Access HIV combo V2 and respectively Prism HIV O Plus (Abbott) or Architect HIV Ag/Ab Combo (Abbott) for Ag/Ab screening, and Procleix Ultrio (Gen Probe) for HIV RNA screening. Limit of detection for p24 antigen was assessed on recombinant virus-like particles (10 HIV-1 group M subtypes/CRFs, HIV-1 group O). Sensitivity [95% confidence interval (CI)] of Access HIV combo V2 was 100% (99.63-100) for HIV-1 chronic infection, 100% (98.55-100) for HIV-2 chronic infection, and 100% (93.00-100) for HIV-1 primary infection. Specificity (95% CI) was 99.98 (99.91-100). Limit of detection for p24 antigen was around 0.43 IU/mL [interquartile range (0.38-0.56)], and consistent across the 11 analyzed subtypes/CRFs. Hence, with both high sensitivity and specificity, Access HIV combo V2 is a suitable screening assay for HIV-1/2 infection.

IMPORTANCE: Bio-Rad is one of the leading human immunodeficiency virus (HIV) screening test manufacturers. This laboratory released in 2021 their new version of the Access combo HIV test. However, to date, there have been no studies regarding its performance, especially its limit of detection of the diverse p24 antigen. We present the sensitivity (chronic and primary HIV-1 infection and HIV-2 chronic infection), specificity (blood donors and hospitalized patients), and raw data for the p24/seroconversion panels the manufacturer gave to the European agencies.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app