A continuous cuffless blood pressure measurement from optimal PPG characteristic features using machine learning algorithms.

Heliyon 2024 March 31
BACKGROUND AND OBJECTIVE: Hypertension is a potentially dangerous health condition that can be detected by measuring blood pressure (BP). Blood pressure monitoring and measurement are essential for preventing and treating cardiovascular diseases. Cuff-based devices, on the other hand, are uncomfortable and prevent continuous BP measurement.

METHODS: In this study, a new non-invasive and cuff-less method for estimating Systolic Blood Pressure (SBP), Mean Arterial Pressure (MAP), and Diastolic Blood Pressure (DBP) has been proposed using characteristic features of photoplethysmogram (PPG) signals and nonlinear regression algorithms. PPG signals were collected from 219 participants, which were then subjected to preprocessing and feature extraction steps. Analyzing PPG and its derivative signals, a total of 46 time, frequency, and time-frequency domain features were extracted. In addition, the age and gender of each subject were also included as features. Further, correlation-based feature selection (CFS) and Relief F feature selection (ReliefF) techniques were used to select the relevant features and reduce the possibility of over-fitting the models. Finally, support vector regression (SVR), K-nearest neighbour regression (KNR), decision tree regression (DTR), and random forest regression (RFR) were established to develop the BP estimation model. Regression models were trained and evaluated on all features as well as selected features. The best regression models for SBP, MAP, and DBP estimations were selected separately.

RESULTS: The SVR model, along with the ReliefF-based feature selection algorithm, outperforms other algorithms in estimating the SBP, MAP, and DBP with the mean absolute error of 2.49, 1.62 and 1.43 mmHg, respectively. The proposed method meets the Advancement of Medical Instrumentation standard for BP estimations. Based on the British Hypertension Society standard, the results also fall within Grade A for SBP, MAP, and DBP.

CONCLUSION: The findings show that the method can be used to estimate blood pressure non-invasively, without using a cuff or calibration, and only by utilizing the PPG signal characteristic features.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app