Streamlining regular liquid chromatography with MALDI-TOF MS and NMR spectroscopy using automatic full-contact splitless spotting interface and flash-tap fractioning collection.

BACKGROUND: High-resolution matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) and nuclear magnetic resonance (NMR) spectroscopy are powerful tools to identify unknown psychoactive substances. However, in complex matrices, trace levels of unknown substances usually require additional fractionation and concentration. Specialized liquid chromatography systems are necessary for both techniques. The small flow rate of nano LC, typically paired with MALDI-TOF MS, often results in prolonged fractionation times. Conversely, the larger flow rate of semi-preparative LC, used for NMR analysis, can be time-consuming and labor-intensive when concentrating samples. To address these issues, we developed an integrated automatic system that integrated to regular LC.

RESULT: Automatic spot collector (ASC) and automatic fraction collector (AFC) were present in this study. The ASC utilized in-line matrix mixing, full-contact spotting and real time heating (50 °C), achieving great capacity of 5 μL droplet on MALDI plate, high recovery (76-116%) and rapid evaporation in 2 min. The analytes were concentrated 4-8 times, forming even crystallization, reaching the detection limit at the concentration of 50 μg L-1 for 12 psychoactive substances in urine. The AFC utilizes flexible tubing which flash-tapped the microtube's upper rim (3 mm depth) instead of reaching the bottom. This method prevents sample loss and minimizes the robotic arm's movement, providing a high fractionating speed at 6 s 12 psychoactive compounds were fractionated in a single round analysis (recovery: 81%-114%). Methamphetamine and nitrazepam obtained from drug-laced coffee samples were successful analyzed with photodiode array (PDA) after one AFC round and NMR after five rounds.

SIGNIFICANCE: The ASC device employed real-time heating, in-line matrix mixing, and full-contact spotting to facilitate the samples spotting onto the MALDI target plate, thereby enhancing detection sensitivity in low-concentration and complex samples. The AFC device utilized the novel flash-tapping method to achieve rapid fractionation and high recovery rate. These devices were assembled using commercially available components, making them affordable (400 USD) for most laboratories while still meeting the required performance for advanced commercialized systems.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app