Add like
Add dislike
Add to saved papers

Hydraulic containment of TCE contaminated groundwater using pulsed pump-and-treat: Performance evaluation and vapor intrusion risk assessment.

Environmental Pollution 2024 Februrary 29
Remedial actions for groundwater contamination such as containment, in-situ remediation, and pump-and-treat have been developed. This study investigates the hydraulic containment of Trichloroethylene (TCE) contaminated groundwater by using pulsed pump-and-treat technology. The hypothetical research site assumed the operation of pulsed pump-and-treat to manage groundwater contaminated with 0.1 mg/L of TCE. at the pump-and-treat facility. Numerical models, employing MODFLOW and MT3DMS for groundwater flow and contamination simulations, were used for case studies to evaluate the performance and risks of pump-and-treat operation strategies. Evaluation criteria included capture width, removal efficiency, and contaminant leakage. Health risks from TCE leakage were assessed using a vapor intrusion risk assessment tool in adjacent areas. In the facility-scale case study, the capture width of the pump-and-treat was controlled by pumping/injection well operations, including schedules and rates. Pumping/injection well configurations impacted facility efficiencies. Pulsed operation led to TCE leakage downstream. Site-scale case studies simulated contaminant transport through pump-and-treat considering various operation stages (continuous; pulsed), as well as various reactions of TCE in subsurface environment (non-reactive; sorption; sorption and biodegradation). Assuming non-reactive tracer, TCE in groundwater was effectively blocked during continuous operation stage but released downstream in the following pulsed operation stage. Considering chemical reactions, the influences of the pump-and-treat operation followed similar trends of the non-reactive tracer but occurred at delayed times. Groundwater contamination levels were reduced through biodegradation. Cancer and non-cancer risks could occur at points of exposure (POEs) where the contamination levels approached or fell below TCE groundwater standards.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app