Prospective study examining the impact of cerebral angiography on quantitative pupillometer values in the interventional radiology suite.

BMJ Open 2024 Februrary 30
OBJECTIVES: The purpose of this pilot study was to obtain baseline quantitative pupillometry (QP) measurements before and after catheter-directed cerebral angiography (DCA) to explore the hypothesis that cerebral angiography is an independent predictor of change in pupillary light reflex (PLR) metrics.

DESIGN: This was a prospective, observational pilot study of PLR assessments obtained using QP 30 min before and after DCA. All patients had QP measurements performed with the NPi-300 (Neuroptics) pupillometer.

SETTING: Recruitment was done at a single-centre, tertiary-care academic hospital and comprehensive stroke centre in Dallas, Texas.

PARTICIPANTS: Fifty participants were recruited undergoing elective or emergent angiography. Inclusion criteria were a physician-ordered interventional neuroradiological procedure, at least 18 years of age, no contraindications to PLR assessment with QP, and nursing transport to and from DCA. Patients with a history of eye surgery were excluded.

MAIN OUTCOME MEASURES: Difference in PLR metric obtained from QP 30 min before and after DCA.

RESULTS: Statistically significant difference was noted in the pre and post left eye readings for the minimum pupil size (a.k.a., pupil diameter on maximum constriction). The mean maximum constriction diameter prior to angiogram of 3.2 (1.1) mm was statistically larger than after angiogram (2.9 (1.0) mm; p<0.05); however, this was not considered clinically significant. Comparisons for all other PLR metrics pre and post angiogram demonstrated no significant difference. Using change in NPi pre and post angiogram (Δpre=0.05 (0.77) vs Δpost=0.08 (0.67); p=0.62), we calculated the effect size as 0.042. Hence, detecting a statistically significant difference in NPi, if a difference exists, would require a sample size of ~6000 patients.

CONCLUSIONS: Our study provides supportive data that in an uncomplicated angiogram, even with intervention, there is no effect on the PLR.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app