Morphometric and clinical comparison of MRI-based synthetic CT to conventional CT of the hip in children.

Pediatric Radiology 2024 Februrary 30
BACKGROUND: MRI-based synthetic CT (sCT) generates CT-like images from MRI data.

OBJECTIVE: To evaluate equivalence, inter- and intraobserver reliability, and image quality of sCT compared to conventional (cCT) for assessing hip morphology and maturity in pediatric patients.

MATERIALS AND METHODS: We prospectively enrolled patients <21 years old with cCT and 3T MRI of the hips/pelvis. A dual-echo gradient-echo sequence was used to generate sCT via a commercially available post-processing software (BoneMRI v1.5 research version, MRIguidance BV, Utrecht, NL). Two pediatric musculoskeletal radiologists measured seven morphologic hip parameters. 3D surface distances between cCT and sCT were computed. Physeal status was established at seven locations with cCT as reference standard. Images were qualitatively scored on a 5-point Likert scale regarding diagnostic quality, signal-to-noise ratio, clarity of bony margin, corticomedullary differentiation, and presence and severity of artifacts. Quantitative evaluation of Hounsfield units (HU) was performed in bone, muscle, and fat tissue. Inter- and intraobserver reliability were measured by intraclass correlation coefficients. The cCT-to-sCT intermodal agreement was assessed via Bland-Altman analysis. The equivalence between modalities was tested using paired two one-sided tests. The quality parameter scores of each imaging modality were compared via Wilcoxon signed-rank test. For tissue-specific HU measurements, mean absolute error and mean percentage error values were calculated using the cCT as the reference standard.

RESULTS: Thirty-eight hips in 19 patients were included (16.6 ± 3 years, range 9.9-20.9; male = 5). cCT- and sCT-based morphologic measurements demonstrated good to excellent inter- and intraobserver correlation (0.77<ICC<0.98). Measurements were statistically equivalent (P < 0.05), with average intermodal differences <2°. Mean surface distance between cCT and sCT was 0.23 ± 0.18 mm. Accuracy to determine physeal maturity status by sCT was 98.4% (242/246, 95% CI 96.0-99.6). No significant differences were found on overall diagnostic quality, bony margin clarity, corticomedullary differentiation, and artifacts between sCT and cCT; signal-to-noise ratio was higher on sCT (P < 0.001). HU were within reference values on both sCT and cCT.

CONCLUSION: sCT is equivalent to cCT for the assessment of hip morphology, physeal status, and radiodensity assessment in pediatric patients.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app