Add like
Add dislike
Add to saved papers

Deformable 3D/3D CT-to-digital-tomosynthesis image registration in image-guided bronchoscopy interventions.

Traditional navigational bronchoscopy procedures rely on preprocedural computed tomography (CT) and intraoperative chest radiography and cone-beam CT (CBCT) to biopsy peripheral lung lesions. This navigational approach is challenging due to the projective nature of radiography, and the high radiation dose, long imaging time, and large footprints of CBCT. Digital tomosynthesis (DTS) is considered an attractive alternative combining the advantages of radiography and CBCT. Only the depth resolution cannot match a full CBCT image due to the limited angle acquisition. To address this issue, preoperative CT is a good auxiliary in guiding bronchoscopy interventions. Nevertheless, CT-to-body divergence caused by anatomic changes and respiratory motion, hinders the effective use of CT imaging. To mitigate CT-to-body divergence, we propose a novel deformable 3D/3D CT-to-DTS registration algorithm employing a multistage, multiresolution approach and using affine and elastic B-spline transformation models with bone and lung mask images. A multiresolution strategy with a Gaussian image pyramid and a multigrid strategy within the B-spline model are applied. The normalized correlation coefficient is included in the cost function for the affine model and a multimetric weighted cost function is used for the B-spline model, with weights determined heuristically. Tested on simulated and real patient bronchoscopy data, the algorithm yields promising results. Assessed qualitatively by visual inspection and quantitatively by computing the Dice coefficient (DC) and the average symmetric surface distance (ASSD), the algorithm achieves mean DC of 0.82±0.05 and 0.74±0.05, and mean ASSD of 0.65±0.29mm and 0.93±0.43mm for simulated and real data, respectively. This algorithm lays the groundwork for CT-aided intraoperative DTS imaging in image-guided bronchoscopy interventions with future studies focusing on automated metric weight setting.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app