Lung ultrasound training: how short is too short? observational study on the effects of a focused theoretical training for novice learners.

BMC Medical Education 2024 Februrary 22
BACKGROUND: Lung ultrasound has been increasingly used in the last years for the assessment of patients with respiratory diseases; it is considered a simple technique, now spreading from physicians to other healthcare professionals as nurses and physiotherapists, as well as to medical students. These providers may require a different training to acquire lung ultrasound skills, since they are expected to have no previous experience with ultrasound. The aim of the study was to assess the impact of a short theoretical training focused on lung ultrasound pattern recognition in a population of novice nurse learners with no previous experience with ultrasound.

METHODS: We included the nurses attending a critical care advanced course for nurses performed at the University of Pavia. Images' interpretation skills were tested on two slide sets (a 25-clip set focused on B-pattern recognition and a 25-clip set focused on identification of pleural movement as lung sliding, lung pulse, lung point, no movement) before and after three 30-minute teaching modules dedicated to general ultrasound principles, B-lines assessment and lung sliding assessment. A cut off of 80% was considered acceptable for correctly interpreted images after this basic course.

RESULTS: 22 nurses were enrolled (age 26.0 [24.0-28.0] years; men 4 (18%)); one nurse had previous experience with other ultrasound techniques, none of them had previous experience with lung ultrasound. After the training, the number of correctly interpreted clips improved from 3.5 [0.0-13.0] to 22.0 [19.0-23.0] (p < 0.0001) for B-pattern and from 0.5 [0.0-2.0] to 8.5 [6.0-12.0] (p < 0.0001) for lung sliding assessment. The number of correct answers for B-pattern recognition was significantly higher than for lung sliding assessment, both before (3.5 [0.0-13.0] vs. 0.5 [0.0-2.0]; p = 0.0036) and after (22.0 [19.0-23.0] vs. 8.5 [6.0-12.0]; p < 0.0001) the training. After the training, nurses were able to correctly recognize the presence or the absence of a B-pattern in 84.2 ± 10.3% of cases; lung sliding was correctly assessed in 37.1 ± 15.3% of cases.

CONCLUSIONS: Lung ultrasound is considered a simple technique; while a short, focused training significantly improves B-pattern recognition, lung sliding assessment may require a longer training for novice learners.

TRIAL REGISTRATION: Not applicable.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app