Add like
Add dislike
Add to saved papers

External validation of the HACOR score and ROX index for predicting treatment failure in patients with coronavirus disease 2019 pneumonia managed on high-flow nasal cannula therapy: a multicenter retrospective observational study in Japan.

Journal of Intensive Care 2024 Februrary 16
BACKGROUND: The HACOR score for predicting treatment failure includes vital signs and acid-base balance factors, whereas the ROX index only considers the respiratory rate, oxygen saturation, and fraction of inspired oxygen (FiO2 ). We aimed to externally validate the HACOR score and ROX index for predicting treatment failure in patients with coronavirus disease 2019 (COVID-19) on high-flow nasal cannula (HFNC) therapy in Japan.

METHODS: This retrospective, observational, multicenter study included patients, aged ≥ 18 years, diagnosed with COVID-19 and treated with HFNC therapy between January 16, 2020, and March 31, 2022. The HACOR score and ROX index were calculated at 2, 6, 12, 24, and 48 h after stating HFNC therapy. The primary outcome was treatment failure (requirement for intubation or occurrence of death within 7 days). We calculated the area under the receiver operating characteristic curve (AUROC) and assessed the diagnostic performance of these indicators. The 2-h time-point prediction was considered the primary analysis and that of other time-points as the secondary analysis. We also assessed 2-h time-point sensitivity and specificity using previously reported cutoff values (HACOR score > 5, ROX index < 2.85).

RESULTS: We analyzed 300 patients from 9 institutions (median age, 60 years; median SpO2 /FiO2 ratio at the start of HFNC therapy, 121). Within 7 days of HFNC therapy, treatment failure occurred in 127 (42%) patients. The HACOR score and ROX index at the 2-h time-point exhibited AUROC discrimination values of 0.63 and 0.57 (P = 0.24), respectively. These values varied with temporal changes-0.58 and 0.62 at 6 h, 0.70 and 0.68 at 12 h, 0.68 and 0.69 at 24 h, and 0.75 and 0.75 at 48 h, respectively. The 2-h time-point sensitivity and specificity were 18% and 91% for the HACOR score, respectively, and 3% and 100% for the ROX index, respectively. Visual calibration assessment revealed well calibrated HACOR score, but not ROX index.

CONCLUSIONS: In COVID-19 patients receiving HFNC therapy in Japan, the predictive performance of the HACOR score and ROX index at the 2-h time-point may be inadequate. Furthermore, clinicians should be mindful of time-point scores owing to the variation of the models' predictive performance with the time-point. Trial registration UMIN (registration number: UMIN000050024, January 13, 2023).

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app