Add like
Add dislike
Add to saved papers

Performance evaluation of Truenat MTB and Truenat MTB-RIF DX assays in comparison to gene XPERT MTB/RIF ultra for the diagnosis of pulmonary tuberculosis in Uganda.

BMC Infectious Diseases 2024 Februrary 14
BACKGROUND: The World Health Organization endorsed Truenat MTB rapid molecular assay in 2020 and recommended additional in-country evaluation studies before uptake. We evaluated the accuracy and operational feasibility of Truenat MTB assay (Truenat) in comparison with GeneXpert Ultra and culture.

METHODS: In a cross-sectional study of 250 presumptive TB patients, participants were requested to provide a sputum sample on the day of their visit to the clinic. The sputum sample was homogenized and a portion was tested using GeneXpert Ultra as per the routine standard procedure and the other portion was tested using Truenat assay at the clinic laboratory. The second sample portion was processed for Concentrated Fluorescent smear Microscopy (CFM), LJ, and MGIT cultures. Truenat sensitivity and specificity were compared to GeneXpert Ultra and culture. Test performance characteristics and operational feasibility assessment data through interview of the study laboratory staff were also collected and summarized as proportions and percentages.

RESULTS: Of the 250 participants recruited in the study, the sensitivity and specificity of Truenat was n/N (%, 95%CI); 66/82 (80.5, 70.2-88.4) and 156/159 (98.1, 94.5-99.6) when compared with Ultra, 50/64 (89.3, 66.0-87.4) and 166/180 (92.2, 87.2-95.6) when compared with LJ, 58/71 (81.7,70.7-89.8) and 131/138 (94.9, 89.8-97.9) when compared to MGIT culture and 59/73 (80.8, 69.9-89.1) and 159/169 (94.1,89.3-97.1) when compared to LJ and/or MGIT culture. The sensitivity of Truenat was lower, 14/23 (60.9, 40.6-82.8) among smear-negative compared to 45/50 (90.0, 78.1-96.6) among smear-positive participants but not different by HIV status. There were no special training needs especially among laboratory personnel with previous GeneXpert /molecular test experience, 19/242 (7.8%) error/invalid, and 12 (17,4%) uninterpretable/indeterminate results mainly for rifampicin resistance determination. However, there were 3 (3.5%) of GeneXpert Ultra indeterminate results.

CONCLUSION: Among presumptive TB patients in Uganda, the Truenat assay has high sensitivity and specificity. The Truenat assay has acceptable operational feasibility attributes when compared with the GeneXpert Assay.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app