[The detecting value of virtual non-calcium technique of dual-energy CT for bone marrow edema around nontraumatic osteonecrosis of the femoral head].

Objective: To evaluate the value of virtual non-calcium (VNCa) technique of dual-energy CT (DECT) for detecting bone marrow edema (BME) around nontraumatic osteonecrosis of the femoral head (ONFH) using MRI as reference standard. Methods: Nontraumatic ONFH patients were prospectively studied in the Fourth Medical Center of Chinese PLA General Hospital from October 2022 to May 2023, and their MRI and DECT images were analyzed. The diagnostic efficiency of the subjective assessment of BME around ONFH by two radiologists in VNCa color-coded images were calculated using the MRI results as the reference standard. The BME ranges were compared between VNCa images and MRI. Traditional CT values and VNCa CT values were compared between normal bone marrow and BME. The receiver operator characteristic (ROC) curve was established based on the statistically different CT values, and the area under the curve (AUC) was calculated to find the threshold to distinguish normal bone marrow from BME and evaluate the diagnostic efficacy. Results: Thirty patients with ONFH were included, including 24 males and 6 females, aged (39±12) years. There were 18 bilateral hips and 12 unilateral hips, with a total of 48 hips, 34 hips of which showed BME on MRI. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of subjective detection of BME on VNCa color coded maps by two physicians were 97.1% (33/34) and 97.1% (33/34), 92.9% (13/14) and 71.4% (10/14), 97.1% (33/34) and 89.2% (33/37), 92.9% (13/14) and 90.9% (10/11), 95.8% (46/48) and 89.6% (43/48), respectively, with no statistical difference (all P> 0.05).There was no statistical difference between VNCa color-coded images and MRI in the BME range ( P =1.160). The traditional CT values measured by the two radiologists were in good agreement with VNCa CT values, with intraclass correlation coefficient (ICC) of 0.948 (95% CI : 0.908-0.971) and 0.982 (95% CI : 0.969-0.990), respectively. The traditional CT value of normal bone marrow was (400.7±82.8) HU, and that of BME was (443.7±65.7) HU, with no statistical difference ( P =0.062). The VNCa CT value of normal bone marrow was (-103.1±27.8) HU, and that of BME was (-32.9±25.7) HU, with statistical difference ( P <0.001). The AUC of distinguishing normal bone marrow from BME based on VNCa CT value was 0.958 (95% CI : 0.857-0.995). The best cut-off value was -74.5 HU, and when the VNCa CT value was higher than -74.5 HU, the sensitivity, specificity, PPV, NPV and accuracy of diagnosing BME were 97.1%, 92.9%, 97.1%, 92.9% and 95.8 %, respectively. Conclusion: The VNCa technique of DECT has high efficiency in detecting BME around ONFH, and can accurately demonstrate the range of BME.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app