Add like
Add dislike
Add to saved papers

Topical Anaesthesia Using a Soft Mist Spray Device Allows Comfortable Awake Visualisation of the Airway via Self-Videolaryngoscopy in Volunteers.

Medicina 2024 January 20
Background : During endotracheal intubation, there is a 10% incidence of difficult laryngoscopy, which may result in serious complications. It is important to obtain as much information about the visibility of laryngeal structures before the patient is anaesthetised. Performing awake (video-) laryngoscopy on a patient is uncomfortable and can trigger gagging and coughing reflexes, making visualisation nearly impossible. The objective of this study is to evaluate the effectiveness of a soft mist spray device for airway anaesthesia during awake (video-) laryngoscopy. Methods : Twenty healthy volunteers inhaled through the Trachospray device, which was placed in their mouths. Two 2 mL syringes containing lidocaine at 4% were sprayed into the airway during inspiration. After several minutes, the subjects were asked to perform a videolaryngoscopy on themselves until the glottic structures and the vocal cords were visible. Upon completion of the procedure, all participants were asked to fill out a feedback form. Results : The duration of the videolaryngoscopy to visualisation of the vocal cords averaged 17 ± 13 s. After analysing the data, three distinct groups emerged as follows: Group 1 (70% of participants) showed no response, allowing for easy insertion of the videolaryngoscope. Group 2 (25% of participants) exhibited a light response but still permitted easy insertion and visualisation. One patient demonstrated a clear response with noticeable laryngeal contraction, requiring slightly more effort and discomfort for insertion. In 80% of the participants, the laryngeal structures were visualised according to Cormack-Lehane grade 1. All participants reported a high level of comfort, with an average rating of NRS 8. The anaesthesiologist assessed the level of anaesthesia as good to very good. No adverse events were observed. Conclusions : The Trachospray provided good, reliable, comfortable, and safe topical anaesthesia for awake videolaryngoscopy. This enables a direct visual assessment of the airway and may assist in making decisions regarding airway management for tracheal intubation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app