Improving the Safety of Computed Tomography Through Automated Quality Measurement: A Radiologist Reader Study of Radiation Dose, Image Noise, and Image Quality.

Investigative Radiology 2024 January 26
OBJECTIVES: The Centers for Medicare and Medicaid Services funded the development of a computed tomography (CT) quality measure for use in pay-for-performance programs, which balances automated assessments of radiation dose with image quality to incentivize dose reduction without compromising the diagnostic utility of the tests. However, no existing quantitative method for assessing CT image quality has been validated against radiologists' image quality assessments on a large number of CT examinations. Thus to develop an automated measure of image quality, we tested the relationship between radiologists' subjective ratings of image quality with measurements of radiation dose and image noise.

MATERIALS AND METHODS: Board-certified, posttraining, clinically active radiologists rated the image quality of 200 diagnostic CT examinations from a set of 734, representing 14 CT categories. Examinations with significant distractions, motion, or artifact were excluded. Radiologists rated diagnostic image quality as excellent, adequate, marginally acceptable, or poor; the latter 2 were considered unacceptable for rendering diagnoses. We quantified the relationship between ratings and image noise and radiation dose, by category, by analyzing the odds of an acceptable rating per standard deviation (SD) increase in noise or geometric SD (gSD) in dose.

RESULTS: One hundred twenty-five radiologists contributed 24,800 ratings. Most (89%) were acceptable. The odds of an examination being rated acceptable statistically significantly increased per gSD increase in dose and decreased per SD increase in noise for most categories, including routine dose head, chest, and abdomen-pelvis, which together comprise 60% of examinations performed in routine practice. For routine dose abdomen-pelvis, the most common category, each gSD increase in dose raised the odds of an acceptable rating (2.33; 95% confidence interval, 1.98-3.24), whereas each SD increase in noise decreased the odds (0.90; 0.79-0.99). For only 2 CT categories, high-dose head and neck/cervical spine, neither dose nor noise was associated with ratings.

CONCLUSIONS: Radiation dose and image noise correlate with radiologists' image quality assessments for most CT categories, making them suitable as automated metrics in quality programs incentivizing reduction of excessive radiation doses.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app